C8051F310-TB Silicon Laboratories Inc, C8051F310-TB Datasheet - Page 127

no-image

C8051F310-TB

Manufacturer Part Number
C8051F310-TB
Description
BOARD PROTOTYPING W/C8051F310
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheets

Specifications of C8051F310-TB

Contents
Board
Processor To Be Evaluated
C8051F31x
Interface Type
USB
Silicon Manufacturer
Silicon Labs
Core Architecture
8051
Silicon Core Number
C8051F310
Silicon Family Name
C8051F31x
Kit Contents
Board
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
C8051F310
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
C8051F310/1/2/3/4/5/6/7
12.5. External RC Example
If an RC network is used as an external oscillator source for the MCU, the circuit should be configured as
shown in Figure 12.1, Option 2. The capacitor should be no greater than 100 pF; however, for very small
capacitors, the total capacitance may be dominated by parasitic capacitance in the PCB layout. To deter-
mine the required External Oscillator Frequency Control value (XFCN) in the OSCXCN Register, first
select the RC network value to produce the desired frequency of oscillation. If the frequency desired is
100 kHz, let R = 246 k and C = 50 pF:
3
3
f = 1.23( 10
) / RC = 1.23 ( 10
) / [ 246 x 50 ] = 0.1 MHz = 100 kHz
Referring to the table in SFR Definition 12.4, the required XFCN setting is 010b.
12.6. External Capacitor Example
If a capacitor is used as an external oscillator for the MCU, the circuit should be configured as shown in
Figure 12.1, Option 3. The capacitor should be no greater than 100 pF; however for very small capacitors,
the total capacitance may be dominated by parasitic capacitance in the PCB layout. To determine the
required External Oscillator Frequency Control value (XFCN) in the OSCXCN Register, select the capaci-
tor to be used and find the frequency of oscillation from the equations below. Assume V
= 3.0 V and
DD
C = 50 pF:
f = KF / ( C x V
) = KF / ( 50 x 3 ) MHz
DD
f = KF / 150 MHz
If a frequency of roughly 150 kHz is desired, select the K Factor from the table in SFR Definition 12.4 as
KF = 22:
f = 22 / 150 = 0.146 MHz, or 146 kHz
Therefore, the XFCN value to use in this example is 011b.