C8051F350DK Silicon Laboratories Inc, C8051F350DK Datasheet - Page 54

DEV KIT FOR F350/351/352/353

C8051F350DK

Manufacturer Part Number
C8051F350DK
Description
DEV KIT FOR F350/351/352/353
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheets

Specifications of C8051F350DK

Contents
Evaluation Board, Power Supply, USB Cables, Adapter and Documentation
Processor To Be Evaluated
C8051F35x
Interface Type
USB
Silicon Manufacturer
Silicon Labs
Core Architecture
8051
Silicon Core Number
C8051F350
Silicon Family Name
C8051F35x
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
C8051F350, 351, 352, 353
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1083

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F350DK
Manufacturer:
SiliconL
Quantity:
8
C8051F350/1/2/3
54
Bit 7:
Bit 6:
Bit 5:
Bit 4:
Bit 3:
Bit 2:
Bit 1:
Bit 0:
AD0BUSY AD0CBSY AD0INT
Bit7
R
AD0BUSY: ADC0 Conversion In-Progress Flag.
0: ADC0 is not performing conversions.
1: ADC0 conversion in progress.
AD0CBSY: ADC0 Calibration In-Progress Flag.
0: ADC0 is not performing a calibration.
1: ADC0 calibration in progress.
AD0INT: ADC0 Conversion Complete Interrupt Flag.
This flag must be cleared in software.
0: ADC0 has not completed a conversion since the last time this flag was cleared.
1: ADC0 conversion is complete.
AD0S3C: ADC0 SINC3 Filter Clip Flag.
This error flag indicates that a clip has occurred in the SINC3 filter during the conversion
process.
0: ADC0 SINC3 filter clip did not occur.
1: ADC0 SINC3 filter clip occurred during conversion.
AD0FFC: ADC0 Fast Filter Clip Flag.
This error flag indicates that a clip has occurred in the fast filter during the conversion pro-
cess.
0: ADC0 fast filter clip did not occur.
1: ADC0 fast filter clip occurred during conversion.
AD0CALC: ADC0 Calibration Complete Flag.
0: ADC0 calibration not complete.
1: ADC0 calibration complete.
AD0ERR: ADC0 Error Flag
This bit is set by hardware under the following conditions:
0: ADC0 error did not occur.
1: ADC0 error occurred.
AD0OVR: ADC0 Overrun Flag
This error flag indicates an overrun condition.
0: ADC0 Overrun did not occur.
1: ADC0 Overrun occurred.
Bit6
R
1) A conversion cycle produced an AD0OVR, AD0S3C, or AD0FFC error.
2) A calibration cycle produced a result that is beyond the limits of the offset or gain
register.
SFR Definition 5.9. ADC0STA: ADC0 Status
R/W
Bit5
AD0S3C
R/W
Bit4
AD0FFC AD0CALC AD0ERR
Rev. 1.1
R/W
Bit3
R/W
Bit2
R/W
Bit1
SFR Address:
AD0OVR 00000000
R/W
Bit0
0xE8
Addressable
Reset Value
Bit