EVL6566A-75WES4 STMicroelectronics, EVL6566A-75WES4 Datasheet - Page 13

BOARD DEMO FOR L6563/LL6566A

EVL6566A-75WES4

Manufacturer Part Number
EVL6566A-75WES4
Description
BOARD DEMO FOR L6563/LL6566A
Manufacturer
STMicroelectronics
Type
Power Factor Correctionr
Datasheets

Specifications of EVL6566A-75WES4

Main Purpose
AC/DC, Primary and Secondary Side with PFC
Outputs And Type
1, Isolated
Power - Output
75W
Voltage - Output
19V
Current - Output
4A
Voltage - Input
90 ~ 264VAC
Regulator Topology
Flyback
Board Type
Fully Populated
Utilized Ic / Part
L6563, L6566A, TSM1014
Input Voltage
90 V to 264 V
Output Voltage
19 V
Dimensions
78 mm x 170 mm
Product
Power Management Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Frequency - Switching
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
L6563S, L6566A
Other names
497-8834

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EVL6566A-75WES4
Manufacturer:
ST
0
AN2941
2
Table 1.
Table 2.
Average active load eff.
100% load Eff.
No-load consumption
20% load Eff.
50% load Eff.
100% load eff.
Notes
25% load eff.
50% load eff.
75% load eff.
Notes
Efficiency measurement
EPA rev. 2.0 external power supply compliance
Table 1
mains voltages. As shown, these values are fully compliant with the EPA rev 2.0 external
power supply limits, requiring an average efficiency higher than 87% for output load
between 25% and 100% of the nominal load and no-load consumption lower than
500 mW.
In particular at no load the power consumption is very low, in fact at 230 Vac,
it is just 136 mW and at 115 Vac it is 83 mW.
Overall efficiency compared to “EPA rev. 2.0 EPS”
EPA rev. 4.0 computers power supply compliance
Different from the previous EPS regulation, the “EPA rev. 4.0 computers” requires a
minimum efficiency higher than 80%, measured at 20%, 50% and 100% of nominal load. In
Table 2
computers” requirements is given.
Overall efficiency compared to “EPA rev. 4.0 computers”
Additionally, the “EPA rev.4.0 computers” document poses specific limitations to the
maximum consumption of computers during standby mode, sleep mode and idle state but
this is not sufficient to deduce the required power supply efficiency because the load applied
during these states is not indicated. This information comes from computer manufacturer
19.12
19.13
19.15
Vout
[V]
shows the no-load consumption and the overall efficiency, measured at the nominal
the comparison of the overall efficiency measurements with the “EPA rev. 4.0
19.08 0.00
19.12 980 18.73 22.37 83.7% 19.10 983 18.76 21.50 87.3% 87.0%
19.13 1960 37.50 42.87 87.5% 19.11 1963 37.52 42.12 89.1% 87.0%
19.16 2936 56.23 63.31 88.8% 19.13 2942 56.26 63.33 88.8% 87.0%
19.15 3917 75.01 84.07 89.2% 19.14 3920 75.00 85.26 88.0% 87.0%
Vout
[mA]
1960
3917
[V]
230 V-50 Hz
Iout
785
[mA]
Iout
15.02 18.17
37.50 42.87
75.01 84.07
Pout
[W]
230 V-50 Hz
Pout
0.00
[W]
Pin
[W]
0.136
Doc ID 15447 Rev 3
[W]
Pin
82.6%
87.5%
89.2%
Eff.
87.3%
------
Eff.
19.10
19.11
19.14
Vout
[V]
19.09 0.00
Vout
[V]
[mA]
1963
3920
115 V-60 Hz
Iout
785
[mA]
Iout
115 V-60 Hz
14.99
37.52
75.00
Pout
[W]
Pout
0.00
[W]
17.39
42.12
85.26
Pin
[W]
0.083
Pin
[W]
Efficiency measurement
86.2%
89.1%
88.0%
88.3% 87.0% Pass
Eff.
------
Eff.
80.0% PASS
80.0% PASS
80.0% PASS
<0.5W Pass
EPA4
EPA2
13/37

Related parts for EVL6566A-75WES4