ADM1041-EVAL Analog Devices Inc, ADM1041-EVAL Datasheet - Page 50

no-image

ADM1041-EVAL

Manufacturer Part Number
ADM1041-EVAL
Description
BOARD EVALUATION ADM1041
Manufacturer
Analog Devices Inc
Datasheet

Specifications of ADM1041-EVAL

Main Purpose
AC/DC, Secondary Side
Outputs And Type
1, Non-Isolated
Power - Output
24W
Voltage - Output
12V
Current - Output
2A
Voltage - Input
85 ~ 132VAC
Board Type
Fully Populated
Utilized Ic / Part
ADM1041
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Frequency - Switching
-
Regulator Topology
-
Lead Free Status / Rohs Status
Not Compliant
ADM1041
Table 36. Register 1Bh, Sel CBD/SMBAlert2. Power-On Default from EEPROM Register 811Bh during Power-Up.
Bit No.
7
6
5
4
3
2
1
0
Table 37. Register 1Ch, Manufacturer’s ID. Power-On Default 41h.
Bit No.
7–0
Table 38. Register 1Dh, Revision Register. Power-On Default 01h.
Bit No.
7–4
3–0
Table 39. Register 2Ah, Status1 Mirror. Power-On Default 00h.
These flags are cleared by a register read, provided the fault no longer persists.
Bit No.
7
6
5
4
3
2
1
0
Name
selcbd2 <7>
selcbd2 <6>
selcbd2 <5>
selcbd2 <4>
selcbd2 <3>
selcbd2 <2>
selcbd2 <1>
selcbd2 <0>
Name
Manufacturer’s ID
Code
Name
Major Revision Code
Minor Revision Code
Name
ovfault_L
uvfault_L
ocpto_L
mfg1_L
mfg2_L
mfg3_L
mfg4_L
mfg5_L
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R/W
R
R
R/W
R
R
R
R
R
R
R
R
Description
V
mfg1
mfg2
mfg3
mfg4
m_cbd_w Microprocessor Control of CBD
mfg5
Not used.
Description
This register contains the manufacturer’s ID code for the device. It is used by the manufacturer
for test purposes and should not be read from or written to in normal operation.
Description
These 4 bits denote the generation of the device.
These 4 bits contain the manufacturer’s code for minor revisions to the device. Rev 0 = 0h, Rev
1 = 1h, and so on.
This register is used by the manufacturer for test purposes. It should not be read from or
written to in normal operation.
Description
Overvoltage fault has occurred.
Undervoltage fault has occurred.
Overcurrent has occured and timed out (ocpf is in Status3).
MON1 flag.
MON2 flag.
MON3 flag.
MON4 flag.
MON5 flag.
Note that latched bits are clocked on a low-to-high transmission only. Also note that these
register bits are cleared when read via the SMBus, except if the fault is still present. It is
recommended to read the register again after the faults disappear to ensure reset.
DD
OK b (inverted)
Rev. A | Page 50 of 64