KP-FSD2 Panduit Corp, KP-FSD2 Datasheet - Page 131

KIT FERRULE INS DIN AWG22-14

KP-FSD2

Manufacturer Part Number
KP-FSD2
Description
KIT FERRULE INS DIN AWG22-14
Manufacturer
Panduit Corp
Series
Pan-Term®r
Type
Ferrule Kitr
Datasheet

Specifications of KP-FSD2

Kit Type
Ferrule - Wire End
Values
400 pcs - Assorted Insulated 22 ~ 14 AWG Ferrules
Where Used
To terminate stranded wire for insertion into terminal blocks
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Flammability
Flammability
A number of test procedures have been developed which can be used for the evaluation and comparison of
various materials to support combustion.
UL 94 Vertical Burning Test
Samples of a material, with dimensions 127mm by 12.7mm and the thickness of the intended end use product,
are tested in an unaged “as manufactured” state and in an aged state (seven days at 158°F, 70°C). The test
requires the placement of a precisely controlled flame under a vertically supported specimen for a ten second
period. The controlled flame is removed and the duration of flaming combustion of the specimen is recorded.
When the flaming combustion of the specimen extinguishes, it is immediately subjected to an additional
controlled flame exposure. After the additional ten seconds of exposure, the controlled flame is removed,
and the duration of flaming combustion of the specimen is recorded. A piece of surgical cotton is placed under
the specimen. If drips ignite the cotton, this fact is also recorded.
Materials Classed 94V-0
Requirements:
Materials Classed 94V-1
Requirements:
Materials Classed 94V-2
Requirements:
• None of the specimens will burn with flaming combustion for more than ten seconds after either
• The total flaming combustion time will not exceed 50 seconds for the ten controlled flame applications
• None of the specimens will burn with flaming or glowing combustion up to the holding clamp
• None of the specimens will drip flaming particles that ignite the dry absorbent surgical cotton
• None of the specimens will exhibit glowing combustion that persists for more than 30 seconds after
• None of the specimens will burn with flaming combustion for more than 30 seconds after either
• The total flaming combustion time will not exceed 250 seconds for the ten controlled flame applications
• None of the specimens will burn with flaming or glowing combustion up to the holding clamp
• Specimens may drip flaming particles which burn only briefly, and may not ignite the dry absorbent
• None of the specimens will exhibit glowing combustion that persists for more than 60 seconds after the
• None of the specimens will burn with flaming combustion for more than 30 seconds after either
• The total flaming combustion time will not exceed 250 seconds for the ten controlled flame applications
• None of the specimens will burn with flaming or glowing combustion up to the holding clamp
• Specimens may drip flaming particles which burn only briefly, and may ignite the dry absorbent surgical
• None of the specimens will exhibit glowing combustion that persists for more than 60 seconds after
application of the controlled flame
(two controlled flame applications for each of the five specimens)
located 12 inches (305mm) below the test specimen
the second removal of the controlled flame
application of the controlled flame
(two controlled flame applications for each of the five specimens)
surgical cotton located 12 inches (305mm) below the test specimen
second removal of the controlled flame
application of the controlled flame
(two controlled flame applications for each of the five specimens)
cotton placed 12 inches (305mm) below the test specimen
the second removal of the controlled flame
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
B1.101
Management
Identification
Accessories
Connectors
Connectors
Grounding
Pre-Printed
& Write-On
Protection
Permanent
Solutions
Cable Ties
Terminals
Lockout/
Overview
Steel Ties
& Safety
Stainless
Raceway
Abrasion
Labeling
Systems
Surface
Markers
Tagout
System
Wiring
Labels
Power
Cable
Cable
Index
Duct
E5.
B1.
B2.
B3.
D1.
D2.
D3.
C1.
C2.
C3.
C4.
E1.
E2.
E3.
E4.
A.
F.