select the (T0/T4)_XSYNC_IN cross-couple Syn-
cLink
tion.
In master mode, the T0 and T4 clock generators may
each operate in the Freerun, Synchronized, or Hold-
over modes:
1. Free Run
In freerun mode, the CLK(0-7) clock outputs are
determined directly from and have the accuracy of
the digitally calibrated free running OCXO/TCXO.
Reference inputs continue to be monitored for signal
presence and frequency offset, but are not used to
synchronize the outputs.
2. Synchronized
The CLK(0-7) clock outputs are phase locked to and
track the selected input reference. Upon entering the
Locking mode, the device begins an acquisition pro-
cess that includes reference qualification and fre-
quency
satisfactory lock is achieved, the “Locked” state is
entered, and the “SYNC” bit is set in the T(0/
4)_DPLL_Status register.
Each DPLL’s loop bandwidth may be set indepen-
dently. Loop bandwidth is selectable from 90mHz to
107Hz, by writing to the T0/4_Bandwidth registers
(0x1d/0x3a).
3. Holdover
Upon entering holdover mode, the CLK(0-7) clock
outputs are determined from the holdover history
established for the last selected reference, or from a
user supplied holdover history. Output frequency is
determined by a weighted average of the holdover
history, and accuracy is determined by the OCXO/
TCXO. Holdover mode may be entered manually or
automatically. Automatic entry into holdover mode
occurs when operating in the automatic mode, the
reference is lost, and no other valid reference exists.
The transfer into and out of holdover mode is
designed to be smooth and free of hits.
Figure 4 shows the phase lock loop states and transi-
tions for operation with automatic reference selection
in Master mode.
TM
data link(s) as the source of phase informa-
slew
rate
limiting,
© Copyright 2006 The Connor-Winfield Corp.
if
needed.
Data Sheet #: TM084
Once
DPLL Operating Mode Details
The T0 and T4 clock generators may operate in the
Freerun, Synchronized, or Holdover modes, includ-
ing some variants thereof:
Freerun Mode
The CLK(0-7) clock outputs are synthesized using
the free running OCXO/TCXO, calibrated with the
freerun frequency offset. The calibration offset may
be programmed by the application by writing to the
Freerun_Cal register, (0x0e/0f). The calibration off-
set may be programmed from -102.4 to +102.3 ppm,
in .1ppm steps, in two’s complement form.
The Freerun mode may be entered automatically,
when in the Automatic Reference Selection mode (as
shown in figure 4), or manually, by writing to the T(0/
4)_Manual_Active_Ref registers.
Figure 4: Device phase lock operational mode transi-
tion in Automatic Refernce Selection/Master Mode
All Rights Reserved
No Reference Available
Page 12 of 44
HO not Available
Synchronous Clock for SETS
and HO Available
Available and
No Reference
Specifications subject to change without notice
Frequency
Locked
Synchronized
Holdover
Locking
Freerun
Locked
Rev: P02
Available
Reference
Any
STC4130
Data Sheet
Reference
Available
Any
Active Reference
not available or
higher priority
reference is
available in
revertive mode
Date: 12/5/06