FDC37C669_07 SMSC [SMSC Corporation], FDC37C669_07 Datasheet - Page 81

no-image

FDC37C669_07

Manufacturer Part Number
FDC37C669_07
Description
PC 98/99 Compliant Super I/O Floppy Disk Controller with Infrared Support
Manufacturer
SMSC [SMSC Corporation]
Datasheet
FIFO INTERRUPT MODE OPERATION
When the RCVR FIFO and receiver interrupts
are enabled (FCR bit 0 = "1", IER bit 0 = "1"),
RCVR interrupts occur as follows:
A. The receive data available interrupt will be
B. The IIR receive data available indication also
C. The receiver line status interrupt (IIR=06H),
D. The data ready bit (LSR bit 0)is set as soon
When RCVR FIFO and receiver interrupts are
enabled, RCVR FIFO timeout interrupts occur
as follows:
A. A FIFO timeout interrupt occurs if all the
issued when the FIFO has reached its
programmed trigger level; it is cleared as
soon
programmed trigger level.
occurs when the FIFO trigger level is
reached. It is cleared when the FIFO drops
below the trigger level.
has higher priority than the received data
available (IIR=04H) interrupt.
as a character is transferred from the shift
register to the RCVR FIFO. It is reset when
the FIFO is empty.
following conditions exist:
- At least one character is in the FIFO
- The most recent serial character received
- The most recent CPU read of the FIFO
This will cause a maximum character
received to interrupt issued delay of 160
msec at 300 BAUD with a 12 bit character.
was longer than 4 continuous character
times ago. (If 2 stop bits are programmed,
the second one is included in this time
delay.)
was longer than 4 continuous character
times ago.
as
the
FIFO
drops
below
its
81
B. Character times are calculated by using the
C. When a timeout interrupt has occurred it is
D. When a timeout interrupt has not occurred
When the XMIT FIFO and transmitter interrupts
are enabled (FCR bit 0 = "1", IER bit 1 = "1"),
XMIT interrupts occur as follows:
A. The transmitter holding register interrupt
B. The transmitter FIFO empty indications will
Character timeout and RCVR FIFO trigger level
interrupts have the sme priority as the current
received data available interrupt; XMIT FIFO
empty has the same priority as the current
transmitter holding register empty interrupt.
FIFO POLLED MODE OPERATION
With FCR bit 0 = "1" resetting IER bits 0, 1, 2 or
3 or all to zero puts the UART in the FIFO
Polled Mode of operation. Since the RCVR and
RCLK input for a clock signal (this makes
the delay proportional to the baudrate).
cleared and the timer reset when the CPU
reads one character from the RCVR FIFO.
the timeout timer is reset after a new
character is received or after the CPU reads
the RCVR FIFO.
(02H) occurs when the XMIT FIFO is empty;
it is cleared as soon as the transmitter
holding register is written to (1 of 16
characters may be written to the XMIT FIFO
while servicing this interrupt) or the IIR is
read.
be delayed 1 character time minus the last
stop bit time whenever the following occurs:
THRE=1 and there have not been at least
two bytes at the same time in the transmitter
FIFO since the last THRE=1. The transmitter
interrupt after changing FCR0 will be
immediate, if it is enabled.