mfr4300 Freescale Semiconductor, Inc, mfr4300 Datasheet - Page 99

no-image

mfr4300

Manufacturer Part Number
mfr4300
Description
Flexray Communication Controllers
Manufacturer
Freescale Semiconductor, Inc
Datasheet
3.3.2.32
This register provides configuration, control, and status information related to the generation and access
of the clock sync ID Tables and clock sync measurement tables. For a detailed description, see
Section 3.4.12, “Sync Frame ID and Sync Frame Deviation
Freescale Semiconductor
0x0044
Reset
SFTOR
CYCNUM
W ELKT OLKT
Field
15–1
R
OLKT
OLKS
ELKT
ELKS
EVAL
OVAL
Field
13–8
15
14
7
6
5
4
15
0
0
Figure 3-31. Sync Frame Table Configuration, Control, Status Register (SFTCCSR)
Sync Frame Table Offset — Offset of the Sync Frame Tables in the FRM. This offset is required to be 16-bit
aligned. Thus STF_OFFSET[0] is always 0.
Sync Frame Table Configuration, Control, Status Register (SFTCCSR)
14
0
0
Even Cycle Tables Lock/Unlock Trigger — This trigger bit is used to lock and unlock the even cycle tables.
0 No effect
1 Triggers lock/unlock of the even cycle tables.
Odd Cycle Tables Lock/Unlock Trigger — This trigger bit is used to lock and unlock the odd cycle tables.
0 No effect
1 Triggers lock/unlock of the odd cycle tables.
Cycle Number — This field provides the number of the cycle in which the currently locked table was
recorded. If none or both tables are locked, this value is related to the even cycle table.
Even Cycle Tables Lock Status — This status bit indicates whether the application has locked the even
cycle tables.
0 Application has not locked the even cycle tables.
1 Application has locked the even cycle tables.
Odd Cycle Tables Lock Status — This status bit indicates whether the application has locked the odd cycle
tables.
0 Application has not locked the odd cycle tables.
1 Application has locked the odd cycle tables.
Even Cycle Tables Valid — This status bit indicates whether the Sync Frame ID and Sync Frame Deviation
Tables for the even cycle are valid. The FlexRay module clears this status bit when it starts updating the
tables, and sets this bit when it has finished the table update.
0 Tables are not valid (update is ongoing)
1 Tables are valid (consistent).
Odd Cycle Tables Valid — This status bit indicates whether the Sync Frame ID and Sync Frame Deviation
Tables for the odd cycle are valid. The FlexRay module clears this status bit when it starts updating the tables,
and sets this bit when it has finished the table update.
0 Tables are not valid (update is ongoing)
1 Tables are valid (consistent).
13
0
Table 3-38. SFTCCSR Field Descriptions (Sheet 1 of 2)
12
0
CYCNUM
11
0
Table 3-37. SFTOR Field Description
10
0
MFR4300 Data Sheet, Rev. 3
0
9
0
8
Description
Description
ELKS OLKS EVAL OVAL
0
7
Tables”.
6
0
0
5
0
4
FlexRay Module (FLEXRAYV2)
0
0
3
OPT
Write: Normal Mode
0
0
2
1
0
0
0
99

Related parts for mfr4300