mfr4300 Freescale Semiconductor, Inc, mfr4300 Datasheet - Page 79

no-image

mfr4300

Manufacturer Part Number
mfr4300
Description
Flexray Communication Controllers
Manufacturer
Freescale Semiconductor, Inc
Datasheet
3.3.2.11
The register holds one set of the protocol related individual interrupt flags. The application clears an
interrupt flag by writing a '1' to it. Writing a ‘0’ will not change the state of the flag. If the application tries
to clear a flag and the FlexRay module sets this flag at the same ¹³×time, then that flag remains set.
Freescale Semiconductor
0x0018
Reset
FATL_IF
INTL_IF
ILCF_IF
W
Field
RBIE
Field
TBIE
R
15
14
13
1
0
15
0
Receive Buffer Interrupt Enable — This flag controls if the receive buffer interrupt line is asserted when the
RBIF flag is set.
0 Disable interrupt line
1 Enable interrupt line
Transmit Interrupt Enable — This flag controls if the transmit buffer interrupt line is asserted when the TBIF
flag is set.
0 Disable interrupt line
1 Enable interrupt line
Fatal Protocol Error Interrupt Flag — This flag is set when the protocol engine has detected a fatal protocol
error. In this case, the protocol engine goes into the
1)
2) transmission across slot boundary violation, as described in the FSP process of the FlexRay protocol
0 No such event.
1 Fatal protocol error detected.
Internal Protocol Error Interrupt Flag — This flag is set when the protocol engine has detected an internal
protocol error. In this case, the protocol engine goes into the
error occurs when the protocol engine has not finished a calculation and a new calculation is requested. This
can be caused by a hardware error.
0 No such event.
1 Internal protocol error detected.
Illegal Protocol Configuration Interrupt Flag — This flag is set when the protocol engine has detected an
illegal protocol configuration parameter setting. In this case, the protocol engine goes into the
immediately.
The protocol engine checks the listen_timeout value programmed into the
(PCR14)
by the application via the
zero, the protocol configuration setting is considered as illegal.
0 No such event.
1 Illegal protocol configuration detected.
Protocol Interrupt Flag Register 0 (PIFR0)
14
0
pLatestTx
13
0
and
violation, as described in the MAC process of the FlexRay protocol
Protocol Configuration Register 15 (PCR15)
Figure 3-10. Protocol Interrupt Flag Register 0 (PIFR0)
12
0
Table 3-16. GIFER Field Descriptions (Sheet 3 of 3)
Table 3-17. PIFR0 Field Descriptions (Sheet 1 of 3)
11
0
Protocol Operation Control Register
10
0
MFR4300 Data Sheet, Rev. 3
0
9
0
8
Description
Description
POC:halt
0
7
when the CONFIG_COMPLETE command was sent
POC:halt
(POCR). If the value of listen_timeout is equal to
6
0
state immediately. The fatal protocol errors are:
0
5
state immediately. An internal protocol
Protocol Configuration Register 14
0
4
FlexRay Module (FLEXRAYV2)
0
3
Write: Normal Mode
0
2
POC:halt
1
0
state
0
0
79

Related parts for mfr4300