fdc37m707 Standard Microsystems Corp., fdc37m707 Datasheet - Page 98

no-image

fdc37m707

Manufacturer Part Number
fdc37m707
Description
Fdc37m707 Enhanced Super I/o Controller With Wake-up Features
Manufacturer
Standard Microsystems Corp.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FDC37M707
Manufacturer:
SMSC
Quantity:
1
Part Number:
FDC37M707
Quantity:
285
Command/Data
ECP Mode supports two advanced features to
improve the effectiveness of the protocol for
some
implemented by allowing the transfer of normal
8 bit data or 8 bit commands.
When in the forward direction, normal data is
transferred when HostAck is high and an 8 bit
command is transferred when HostAck is low.
The most significant bit of the command
indicates whether it is a run-length count (for
compression) or a channel address.
When in the reverse direction, normal data is
transferred when PeriphAck is high and an 8 bit
command is transferred when PeriphAck is low.
The most significant bit of the command is
always zero. Reverse channel addresses are
seldom used and may not be supported in
hardware.
Data Compression
The ECP port supports run length encoded
(RLE) decompression in hardware and can
transfer compressed data to a peripheral. Run
length encoded (RLE) compression in hardware
is not supported. To transfer compressed data
in ECP mode, the compression count is written
to the ecpAFifo and the data byte is written to
the ecpDFifo.
Compression is accomplished by counting
identical bytes and transmitting an RLE byte
that indicates how many times the next byte is
to be repeated.
intercepts the RLE byte and repeats the
Reverse Channel Commands (PeripAck Low)
Forward Channel Commands (HostAck Low)
D7
0
1
applications.
Run-Length Count (0-127)
(mode 0011 0X00 only)
Channel Address (0-127)
Table 40 -
Decompression simply
D[6:0]
The
features
are
98
following byte the specified number of times.
When a run-length count is received from a
peripheral,
replicated the specified number of times. A
run-length count of zero specifies that only one
byte of data is represented by the next data
byte, whereas a run-length count of 127
indicates that the next byte should be expanded
to 128 bytes. To prevent data expansion,
however, run-length counts of zero should be
avoided.
Pin Definition
The drivers for nStrobe, nAutoFd, nInit and
nSelectIn are open-collector in mode 000 and
are push-pull in all other modes.
ISA Connections
The interface can never stall causing the host to
hang. The width of data transfers is strictly
controlled on an I/O address basis per this
specification. All FIFO-DMA transfers are byte
wide, byte aligned and end on a byte boundary.
(The PWord value can be obtained by reading
Configuration Register A, cnfgA, described in
the next section).
are always possible with standard or PS/2 mode
using program control of the control signals.
Interrupts
The interrupts are enabled by serviceIntr in the
ecr register.
serviceIntr = 1 Disables the DMA and all of the
serviceIntr = 0
the
service interrupts.
Enables the selected interrupt
condition.
condition is valid, then the
interrupt
immediately when this bit is
changed from a 1 to a 0. This
can occur during Programmed
I/O if the number of bytes
removed or added from/to the
subsequent
Single byte wide transfers
If the interrupting
is
data
generated
byte
is

Related parts for fdc37m707