LM3S328-IRN20-A0T Luminary Micro, Inc., LM3S328-IRN20-A0T Datasheet - Page 88

no-image

LM3S328-IRN20-A0T

Manufacturer Part Number
LM3S328-IRN20-A0T
Description
Microcontroller
Manufacturer
Luminary Micro, Inc.
Datasheet
System Control
a.
88
Bit/Field
If the unit is unclocked, a read or write to the unit generates a bus fault.
7:4
2:0
3
reserved
reserved
Name
WDT
Type
R/W
RO
RO
Reset
Preliminary
0
0
0
Description
Reserved bits return an indeterminate value, and should
never be changed.
This bit controls the clock gating for the WDT module. If
set, the unit receives a clock and functions. Otherwise, the
unit is unclocked and disabled.
Reserved bits return an indeterminate value, and should
never be changed.
a
April 27, 2007