GS1560A Gennum Corporation, GS1560A Datasheet - Page 47

no-image

GS1560A

Manufacturer Part Number
GS1560A
Description
Reclocking Deserializer For HD-SDI, Sd-sdi & Dvb-asi With Loop Thru Cable Driver. 3.3/1.8V Supply.
Manufacturer
Gennum Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
GS1560A
Manufacturer:
GENNUM
Quantity:
748
Part Number:
GS1560ACFE3
Manufacturer:
MURATA
Quantity:
47 600
Part Number:
GS1560ACFE3
Manufacturer:
GUNNUM
Quantity:
310
Part Number:
GS1560ACFE3
Manufacturer:
GUNNUM
Quantity:
1
3.10.6.5 HD Line Number Error Correction
In HD mode, the GS1560A will calculate and insert line
numbers into the Y and C channels of the output data
stream.
Line number generation is in accordance with the relevant
HD video standard as determined by the device, (see
section 3.10.4).
This feature is enabled when SD/HD = LOW, and the
LNUM_INS bit of the IOPROC_DISABLE register is set LOW.
3.10.6.6 TRS Error Correction
When TRS error correction and insertion is enabled, the
GS1560A will generate and insert 10-bit TRS code words as
required.
TRS word generation will be performed in accordance with
the timing parameters generated by the flywheel to provide
an element of noise immunity. As a result, TRS correction
Table 15: Host Interface Description for EDH Flag Register
GENNUM CORPORATION
REGISTER NAME
Address: 003h
EDH_FLAG
BIT
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
ANC-EDA out
ANC-EDH out
ANC-UES out
ANC-IDH out
ANC-IDA out
AP-EDH out
AP-UES out
AP-EDA out
FF-UES out
FF-EDA out
FF-EDH out
AP-IDA out
AP-IDH out
FF-IDA out
FF-IDH out
NAME
Active Picture Unknown Error Status Flag.
Ancillary Unknown Error Status Flag.
Ancillary Internal device error Detected Already Flag.
Ancillary Internal device error Detected Here Flag.
Ancillary Error Detected Already Flag.
Ancillary Error Detected Here Flag.
Full Field Unknown Error Status Flag.
Full Field Internal device error Detected Already Flag.
Full Field Internal device error Detected Here Flag.
Full Field Error Detected Already Flag.
Full Field Error Detected Here Flag.
Active Picture Internal device error Detected Already Flag.
Active Picture Internal device error Detected Here Flag.
Active Picture Error Detected Already Flag.
Active Picture Error Detected Here Flag.
47 of 55
will only take place if the flywheel is enabled, (FW_EN/DIS =
HIGH).
In addition, the TRS_INS bit of the IOPROC_DISABLE
register must be set LOW.
3.10.7 EDH Flag Detection
As described in section 3.10.5.2, the GS1560A can detect
EDH packets in the received data stream. The EDH flags for
ancillary data, active picture and full field areas are
extracted from the detected EDH packets and placed in the
EDH_FLAG register of the device (Table 15).
One set of flags is provided for both fields 1 and 2. Field 1
flag data will be overwritten by field 2 flag data.
NOTE: The GS1560A will detect EDH flags, but will not
update the flags if an EDH CRC error is detected.
Gennum's GS1532 Multi-Rate Serializer allows the host to
individually set EDH flags.
DESCRIPTION
Not Used
R/W
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
DEFAULT
27360-1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0