ATtiny43U Atmel Corporation, ATtiny43U Datasheet - Page 29

no-image

ATtiny43U

Manufacturer Part Number
ATtiny43U
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATtiny43U

Flash (kbytes)
4 Kbytes
Pin Count
20
Max. Operating Frequency
8 MHz
Cpu
8-bit AVR
# Of Touch Channels
8
Hardware Qtouch Acquisition
No
Max I/o Pins
16
Ext Interrupts
16
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
4
Adc Resolution (bits)
10
Adc Speed (ksps)
15
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
0.25
Eeprom (bytes)
64
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
0.7 to 5.5
Operating Voltage (vcc)
0.7 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
2
Output Compare Channels
4
Pwm Channels
4
32khz Rtc
No
Calibrated Rc Oscillator
Yes
8048B–AVR–03/09
cleared by hardware four cycles after it is written or when CLKPS bits are written. Rewriting the
CLKPCE bit within this time-out period does neither extend the time-out period, nor clear the
CLKPCE bit.
• Bits 3:0 – CLKPS[3:0]: Clock Prescaler Select Bits 3 - 0
These bits define the division factor between the selected clock source and the internal system
clock. These bits can be written run-time to vary the clock frequency to suit the application
requirements. As the divider divides the master clock input to the MCU, the speed of all synchro-
nous peripherals is affected. The division factors are given in
The CKDIV8 Fuse determines the initial value of the CLKPS bits. If CKDIV8 is unprogrammed,
the CLKPS bits will be reset to “0000”. If CKDIV8 is programmed, CLKPS bits are reset to
“0011”, giving a division factor of 8 at start up. This feature should be used if the selected clock
source has a higher frequency than the maximum frequency of the device at the present operat-
ing conditions. Note that any value can be written to the CLKPS bits regardless of the CKDIV8
Fuse setting. The Application software must ensure that a sufficient division factor is chosen if
the selected clock source has a higher frequency than the maximum frequency of the device at
the present operating conditions. The device is shipped with the CKDIV8 Fuse programmed.
Table 6-9.
To avoid unintentional changes of clock frequency, a special write procedure must be followed
to change the CLKPS bits:
1. Write the Clock Prescaler Change Enable (CLKPCE) bit to one and all other bitsin
2. Within four cycles, write the desired value to CLKPS while writing a zero to CLKPCE.
CLKPS3
CLKPR to zero.
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
Clock Prescaler Select
CLKPS2
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
CLKPS1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
CLKPS0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Table
6-9.
Clock Division Factor
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
128
256
16
32
64
1
2
4
8
29