MD3331-D64-V3-X SanDisk, MD3331-D64-V3-X Datasheet - Page 26

no-image

MD3331-D64-V3-X

Manufacturer Part Number
MD3331-D64-V3-X
Description
Manufacturer
SanDisk
Type
Flash Diskr
Datasheet

Specifications of MD3331-D64-V3-X

Density
64MByte
Operating Supply Voltage (typ)
3.3V
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Package Type
FBGA
Mounting
Surface Mount
Pin Count
69
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.5V
Operating Supply Voltage (max)
3.6V
Programmable
Yes
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MD3331-D64-V3-X
Manufacturer:
SANDISK
Quantity:
18 135
Part Number:
MD3331-D64-V3-X
Manufacturer:
TI
Quantity:
699
Part Number:
MD3331-D64-V3-X
Quantity:
1 000
Part Number:
MD3331-D64-V3-X
Manufacturer:
M-SYSTEMS
Quantity:
20 000
Company:
Part Number:
MD3331-D64-V3-X
Quantity:
24
Company:
Part Number:
MD3331-D64-V3-X
Quantity:
1 545
5.
Mobile DiskOnChip Plus has three modes of operation:
Mode changes can occur due to any of the following events, as shown in Figure 9:
26
Reset
Normal
Deep Power-Down
Assertion of the RSTIN# signal sets the device in Reset mode.
During power-up, boot detector circuitry sets the device in Reset mode.
A valid write sequence to Mobile DiskOnChip Plus sets the device in Normal mode. This is
done automatically by the TrueFFS driver on power-up (reset sequence end).
Switching back from Normal mode to Reset mode can be done by a valid write sequence to
Mobile DiskOnChip Plus, or by triggering the boot detector circuitry (by soft reset).
Power-down.
A valid write sequence, initiated by software, sets the device from Normal mode to Deep
Power-Down mode. Four read cycles from offset 0x1FFF set the device back to Normal mode.
Alternately, the device can be set back to Normal mode with an extended access time during a
read from the Programmable Boot Block (see Section 10.4.1 for read cycle timing).
Asserting the RSTIN# signal and holding it in this state while in Normal mode puts the device
in Deep Power-Down mode. When the RSTIN# signal is released, the device is set in Reset
mode.
M
ODES OF
Power-Down
Power-Down
Power Off
O
Mode
PERATION
Deep
Figure 9: Operation Modes and Related Events
Power-Down
Assert RSTIN#
Release RSTIN#
Data Sheet, Rev. 1.8
4x Read Cycles from
extended read cycle
Software Control
offset 0x1FFF or
Assert RSTIN#
Power-Down
Power-Up
Software Control
Assert RSTIN#,
Boot Detect or
Normal Mode
Reset Mode
Mobile DiskOnChip Plus 16/32MByte
Sequence
Reset
End
95-SR-000-10-8L

Related parts for MD3331-D64-V3-X