KM29W040AT Samsung Semiconductor, KM29W040AT Datasheet - Page 20

no-image

KM29W040AT

Manufacturer Part Number
KM29W040AT
Description
Manufacturer
Samsung Semiconductor
Datasheet

Specifications of KM29W040AT

Cell Type
NAND
Density
4Mb
Access Time (max)
15us
Interface Type
Parallel
Boot Type
Not Required
Address Bus
8b
Operating Supply Voltage (typ)
3.3/5V
Operating Temp Range
0C to 70C
Package Type
TSOP-II
Sync/async
Asynchronous
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
3V
Operating Supply Voltage (max)
5.5V
Word Size
8b
Number Of Words
512K
Supply Current
20mA
Mounting
Surface Mount
Pin Count
40
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KM29W040AT
Quantity:
6
Part Number:
KM29W040AT
Manufacturer:
OSRAM
Quantity:
5 000
Table3. Device Status
R/B
I/O
READY/BUSY
The device has a R/B output that provides a hardware method of indicating the completion of a frame program, erase or read seek
completion. The R/B pin is normally high but transitions to low after program or erase command is written to the command register or
a random read is begin after address loading. It returns to high when the internal controller has finished the operation. The pin is an
open-drain driver thereby allowing two or more R/B outputs to be Or-tied. An appropriate pull-up resister is required for proper opera-
tion and the value may be calculated by following equation.
RESET
The device offers a reset feature, executed by writing FFH to the command register. When the device is in Busy state during the
read, program or erase mode, the reset operation will abort these operation. In the case of Reset during Program or Erase opera-
tions, the contents of memory cells being altered are no longer valid, as the data will be partially programmed or erased. The device
enters the Read mode after completion of Reset operation as shown Table 3. If the device is already in reset state a new reset com-
mand will not be accepted to by the command register. The R/B pin transitions to low for t
Reset command is not necessarily for normal device operation. Refer to Figure 7 below.
Figure 7. RESET Operation
KM29W040AT, KM29W040AIT
0
~
V
7
CC
GND
Operation Mode
Device
FFH
R/B
open drain output
After Power-up
Read
Note*
where I
R/B pin.
Rp =
t
RST
20
KM29W040A ; 5.1V when Vcc=3.6V~5.5V
L
V
is the sum of the input currents of all devices tied to the
CC
(Max.) - V
I
OL
+ I
3.2V when Vcc=3.0V~3.6V
OL
L
(Max.)
RST
after the Reset command is written.
=
FLASH MEMORY
After Reset
Read
8mA + I
Note*
L

Related parts for KM29W040AT