Z16M1720ASG1868 Zilog, Z16M1720ASG1868 Datasheet - Page 271

no-image

Z16M1720ASG1868

Manufacturer Part Number
Z16M1720ASG1868
Description
IC PCMCIA INTERFACE 100-VQFP
Manufacturer
Zilog
Datasheet

Specifications of Z16M1720ASG1868

Applications
*
Interface
*
Voltage - Supply
*
Package / Case
100-LQFP
Mounting Type
Surface Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z16M1720ASG1868
Manufacturer:
Zilog
Quantity:
10 000
UM008101-0601
Note:
before the next character is transferred, CRC is calculated on the transferred
character. If CRC is disabled before the time of the next transfer, calcula-
tion proceeds on the word in progress, but the word just transferred to the
buffer is not included. When these requirements are satisfied, the 3-byte
receive data buffer is, in effect, unusable in Bisync operation. CRC may be
enabled and disabled as many times as necessary for a given calculation.
In the Monosync, Bisync, and External Sync modes, the CRC/Framing Error
bit (RR1, D6) contains the comparison result of the CRC checker 16-bit
times (eight bits delay and eight shifts for CRC) after the character has been
transferred from the receive shift register to the buffer. The result should be
zero, indicating an error-free transmission.
The comparison is made with each transfer and is valid only as long as the
character remains in the receive FIFO.
Following is an example of the CRC checking operation when four charac-
ters (A, B, C, and D) are received in that order.
If CRC is disabled before C is in the buffer, CRC is not calculated on B.
After C is loaded, the CRC/Framing Error bit shows the result of the
comparison through character A.
After D is in the buffer, the CRC Error bit shows the result of the comparison
through character B whether or not B was included in the CRC calculations.
Due to the serial nature of CRC calculation, the Receive Clock (RxC)
must cycle 16 times (8-bit delay plus 8-bit CRC shift) after the second
Character A loaded to buffer
Character B loaded to buffer
Character C loaded to buffer
Character D loaded to buffer
The result is valid only at the end of CRC calculation. If the result
is examined before this time, it usually indicates an error.
Z80 CPU Peripherals
Serial Input/Output
User Manual
251