XW2B-80J7-1A Omron, XW2B-80J7-1A Datasheet - Page 334

no-image

XW2B-80J7-1A

Manufacturer Part Number
XW2B-80J7-1A
Description
RELAY UNIT
Manufacturer
Omron
Datasheet

Specifications of XW2B-80J7-1A

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2B80J71A
Overview of System Setups
A System Setup contains software settings that the user can change to customize FQM1 operation. Module
functions are set using its System Setup.
The Coordinator Module and Motion Control Modules all have System Setups, which are set from the CX-Pro-
grammer to customize operation for the following types of applications.
The addresses given for the settings in the System Setup are not required for actually making the settings. Use
the menus of the CX-Programmer Ver. 5.0@.
System Setup in the Coordinator Module
Sync Settings between Modules (CX-Programmer: Module Settings Tab Page)
Allow Writing to User Memory
Prohibit System Interrupt of the Sync Mode
• When programming the FQM1 for the first time and the Motion Control
• When editing or debugging the program in a specific Motion Control Mod-
• When you want the FQM1 to go into RUN mode or MONITOR mode and
• When you want the operating mode to be other than RUN mode when the
When the peripheral port will not be used with the CX-Programmer (periph-
eral bus) communications speed auto-detection and will not be used with the
default Host Link communications settings, such as 9,600 bps.
When the RS-232C port will not be used with the CX-Programmer (periph-
eral bus) communications speed auto-detection and will not be used with the
default Host Link communications settings, such as 9,600 bps.
When you want to communicate with a PT via an NT Link.
You want a constant (minimum) cycle time setting to create a consistent I/O
refresh cycle or cycle time.
You want to set a maximum cycle time other than 50 ms (1 ms to 100 ms).
You want to extend peripheral servicing time because peripheral services
are being executed over several cycles, delaying completion of servicing
(want to set a specific time rather than a percent of the cycle time).
+304
+304
Modules are being programmed before the Coordinator Module.
ule.
start operating immediately after startup.
power is turned ON.
Word
Word
Address
Address
00
08
Bits
Bits
Cases when settings must be changed
0: Writing enabled
1: Writing disabled
Default: Writing enabled
0: Not prohibited
1: Prohibited
Default: Not prohibited
System Setup, Auxiliary Area Allocations,
Settings
Settings
and Built-in I/O Allocations
Sets and releases write-protection for
the user memory and System Setup.
Sets and releases prohibition of system
interrupts during program execution.
Set to 1: Prohibit coordinating (match-
ing) the operation start timings among
Modules in Sync Mode.
Appendix C
Function
Function
Peripheral Port Settings or Host Link Port Settings
Watch Cycle Time
Sync Mode
Startup Mode
Peripheral Port Settings
Host Link Port Settings
Cycle Time
Set Time to All Events
---
---
Setting(s) to be changed
Related flags and
Related flags and
words
words
power ON or at
start of operation
When enabling:
When changed
tion
When disabling: At
At start of opera-
When setting is
When setting is
read
read
311