PEF81902FV1.1 Lantiq, PEF81902FV1.1 Datasheet - Page 86

no-image

PEF81902FV1.1

Manufacturer Part Number
PEF81902FV1.1
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEF81902FV1.1

Lead Free Status / RoHS Status
Supplier Unconfirmed
RES
SSP
TIM
U-Interface Events
U0
U2
U4H
AWR
AWT
LOF
TxE
Timers
The start of timers is indicated by TxS, the expiry by TxE. The following table shows
which timers are used.
Table 20
Timer
T05
T6
Data Sheet
Reset
Unconditional command which resets the U-transceiver.
Send Single Pulses
Unconditional command which requests the transmission of single pulses on
the U-interface.
Timing
The U-transceiver is requested to enter state ’IOM Awaked’.
U0 detected
U0 is recognized after 120 symbols (1ms) with zero level in a row. Detection
may last up to 2 ms.
U2 detected
The U-transceiver detects U2 if continuous binary 0‘s are found after
descrambling and LOF = 0 for at least 8 subsequent U-frames. U2 is detected
after 8 to 9 ms.
U4H detected
U4H is recognized, if the U-transceiver detects 16 subsequent binary 1’s after
descrambling.
Awake signal (U2W) detected
Awake signal (U1W) has been sent out
Loss of Framing on U-interface
Timer ended, the started timer has expired
Duration (ms)
0.5
6
Timers
Function
C/I code recognition
Supervises U1W repetition
72
Functional Description
State
Start Awaking Uk0
Pend. Deactivation,
Deactivating
PEF 81902
2001-11-12

Related parts for PEF81902FV1.1