82V3280EQG Integrated Device Technology (Idt), 82V3280EQG Datasheet - Page 110

no-image

82V3280EQG

Manufacturer Part Number
82V3280EQG
Description
WAN PLL 100-Pin TQFP Tray
Manufacturer
Integrated Device Technology (Idt)
Datasheet

Specifications of 82V3280EQG

Package
100TQFP
Operating Temperature
-40 to 85 °C

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
82V3280EQG
Manufacturer:
IDT
Quantity:
20 000
IN3_IN4_STS - Input Clock 3 & 4 Status
Address: 44H
Type: Read
Default Value: X110X110
Programming Information
IDT82V3280
Bit
7
6
5
4
3
2
1
0
7
-
IN4_FREQ_HAR
IN4_NO_ACTIVITY_ALARM
IN3_NO_ACTIVITY_ALARM
IN4_FREQ_HARD_ALARM
IN3_FREQ_HARD_ALARM
D_ALARM
IN4_PH_LOCK_ALARM
IN3_PH_LOCK_ALARM
6
Name
-
-
IN4_NO_ACTIVI
TY_ALARM
5
Reserved.
This bit indicates whether IN4 is in frequency hard alarm status.
0: No frequency hard alarm.
1: In frequency hard alarm status. (default)
This bit indicates whether IN4 is in no-activity alarm status.
0: No no-activity alarm.
1: In no-activity alarm status. (default)
This bit indicates whether IN4 is in phase lock alarm status.
0: No phase lock alarm. (default)
1: In phase lock alarm status.
If the PH_ALARM_TIMEOUT bit (b5, 09H) is ‘0’, this bit is cleared by writing ‘1’ to this bit; if the
PH_ALARM_TIMEOUT bit (b5, 09H) is ‘1’, this bit is cleared after a period ( = TIME_OUT_VALUE[5:0] (b5~0,
08H) X MULTI_FACTOR[1:0] (b7~6, 08H) in second ) which starts from when the alarm is raised.
Reserved.
This bit indicates whether IN3 is in frequency hard alarm status.
0: No frequency hard alarm.
1: In frequency hard alarm status. (default)
This bit indicates whether IN3 is in no-activity alarm status.
0: No no-activity alarm.
1: In no-activity alarm status. (default)
This bit indicates whether IN3 is in phase lock alarm status.
0: No phase lock alarm. (default)
1: In phase lock alarm status.
If the PH_ALARM_TIMEOUT bit (b5, 09H) is ‘0’, this bit is cleared by writing ‘1’ to this bit; if the
PH_ALARM_TIMEOUT bit (b5, 09H) is ‘1’, this bit is cleared after a period ( = TIME_OUT_VALUE[5:0] (b5~0,
08H) X MULTI_FACTOR[1:0] (b7~6, 08H) in second ) which starts from when the alarm is raised.
IN4_PH_LOCK_
ALARM
4
110
3
-
IN3_FREQ_HAR
D_ALARM
Description
2
IN3_NO_ACTIVI
TY_ALARM
1
December 9, 2008
IN3_PH_LOCK_
ALARM
0
WAN PLL