CVM1-PA208 Omron, CVM1-PA208 Datasheet - Page 117

no-image

CVM1-PA208

Manufacturer Part Number
CVM1-PA208
Description
CV/CVM1 POWER SUPPLY, AC
Manufacturer
Omron
Datasheet

Specifications of CVM1-PA208

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
5-3-3 Replacing Fuses
5-3-4 Replacing Relays
I/O Unit Online Replacement
1, 2, 3...
1, 2, 3...
To replace a fuse in an Output Unit, take the following steps. Use the following
fuses.
To replace a Relay in an Output Unit, take the following steps. Use the following
relays.
C500-OD411, C500-OD217, and
C500-OA223
C500-OA121 or C500-OA222
C500-OD219
C500-OD221, C500-OD223, and
C500-OD224
1. Turn off the power to the PC.
2. Detach the terminal block from the Output Unit by removing the screws lo-
3. Remove the screws that mount the Output Unit to the Backplane. Pull the
4. There are eight screws on each side of the Output Unit. Remove these
5. Pull out the printed circuit board.
6. Replace the fuse with a new one.
7. Reassemble the Unit.
1. Turn off the power to the PC.
cated at the top and bottom of the terminal block.
Output Unit toward you and remove it from the Backplane.
screws to detach the case from the cover.
Unit
Unit
250 V, 5 A
MF51SH (JIS), 20 mm x 5.2 mm dia.
250 V, 5 A
Model SS2 (SOC Corporation),
32 mm x 6.35 mm dia.
250 V, 10 A
GGL-10 (Nagasawa Electric)
G6B-1174P-FD-US-M, 24 VDC
Mounting screws
Located at the top and bottom.
Terminal block mounting screws
Located at the top and bottom of the
terminal block.
Cover mounting screws (8)
Fuse specifications
Fuse specifications
Section
101
5-3