R88A-CAU015S Omron, R88A-CAU015S Datasheet - Page 221

no-image

R88A-CAU015S

Manufacturer Part Number
R88A-CAU015S
Description
POWER CABLE 15M
Manufacturer
Omron
Datasheet

Specifications of R88A-CAU015S

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Application
4-6
The periodic maintenance cycle depends on the installation environment and application conditions of
the Servomotor or Position Driver. Recommended maintenance times are listed below for Servomotors
and Position Drivers. Use these as references in determining actual maintenance schedules.
j Servomotors
j Position Drivers
4-30
!
!
Recommended Periodic Maintenance
Application Conditions: Ambient motor operating temperature of 40 C, within allowable shaft load,
The radial loads during operation (rotation) on timing pulleys and other components contacting belts is
twice the still load. Consult with the belt and pulley manufacturers and adjust designs and system set-
tings so that the allowable shaft load is not exceeded even during operation. If a motor is used under a
shaft load exceeding the allowable limit, the motor shaft can break, the bearings can burn out, and
other problems can occur.
Recommended Periodic Maintenance
Application Conditions: Rated operation (rated torque) and installation as described in the User’s
The life of aluminum analytical capacitors is greatly affected by the ambient operating temperature.
Generally speaking, an increase of 10 C in the ambient operating temperature will reduce capacitor
life by 50%. We recommend that ambient operating temperature be lowered and the power supply
time be reduced as much as possible to lengthen the maintenance times for Position Drivers.
It is recommended that the Position Driver be inspected at five-year intervals if they are used under
conditions worse than the above or not used over a long time of time. Contact your OMRON represen-
tative for inspection and the necessity of any component replacement.
WARNING
Caution
Oil Seal:
Bearings: 20,000 hours (U Series); 30,000 hours (H Series, M Series)
Aluminum analytical capacitors:
Fans:
Servomotors and Position Drivers contain many components and will operate properly
only when each of the individual components is operating properly. Some of the electri-
cal and mechanical components require maintenance depending on application condi-
tions. In order to ensure proper long-term operation of Servomotors and Position Driv-
ers, periodic inspection and part replacement is required according to the service life of
the components.
Periodic Maintenance
2,000 hours
Do not attempt to take the Unit apart or repair. Doing either of these may result in
electrical shock or injury.
Resume operation only after transferring to the new Unit the contents of the data
required for operation. Not doing so may result in equipment damage.
rated operation (rated torque and r/m), installed as described in operation
manual.
Manual.
50,000 hours at ambient temperature of 35 C
55,000 hours at ambient temperature of 20 C
(FND-X50H-
only)
Chapter 4

Related parts for R88A-CAU015S