CJ Position Control Units OPERATION MANUAL (CJ1W-NC214/234/414/434)
WARNING
Caution
Caution
Caution
Caution
Caution
Caution
Provide safety measures in external circuits (i.e., not in the Programmable Controller or
Position Control Unit) to ensure safety in the system if an abnormality occurs due to
malfunction of the PLC, malfunction of the PCU (Position Control Unit), or external factors
affecting the operation of the PLC or PCU.
Not providing sufficient safety measures may result in serious accidents.
When positioning to a position determined using the teaching function, set the position
designation setting in the positioning sequence to absolute positioning.
If it is set to relative positioning, positioning will be performed to a position other than the one
obtained with the teaching function.
Execute online edit only after confirming that no adverse effects will be caused by extending
the cycle time. Otherwise, the input signals may not be readable.
Confirm the safety of the destination node before transferring a program to the node or
changing the contents of I/O memory. Doing either of these without confirming safety may
result in injury.
Do not save data into the flash memory during memory operation or while the motor is
running. Otherwise, unexpected operation may be caused.
Do not reverse the polarity of the 24-V power supply. The polarity must be correct.
Otherwise, the motor may start running unexpectedly and may not stop.
Make sure the unit version of the Position Control Unit is 2.3 or later before using the CW/
CCW Pulse Output Selection Function. Otherwise, the pulse output may be in the opposite
direction from what was intended and the machine may be damaged.
• Emergency stop circuits, interlock circuits, limit circuits, and similar safety measures
• The PLC will turn OFF all outputs when its self-diagnosis function detects any error or
• The PLC or PCU outputs may remain ON or OFF due to deposits on or burning of the
• When the 24-V DC output (service power supply to the PLC) is overloaded or short-
• External safety measures must also be taken to ensure safety in the event of
must be provided in external control circuits.
when a severe failure alarm (FALS) instruction is executed.
Unexpected operation, however, may still occur for errors in the I/O control section,
errors in I/O memory, and other errors that cannot be detected by the self-diagnosis
function. As a countermeasure for all such errors, external safety measures must be
provided to ensure safety in the system.
output relays, or destruction of the output transistors. As a countermeasure for such
problems, external safety measures must be provided to ensure safety in the system.
circuited, the voltage may drop and result in the outputs being turned OFF. As a
countermeasure for such problems, external safety measures must be provided to
ensure safety in the system.
unexpected operation when connecting or disconnecting the PCU's connectors.