10.16 Additional PID functions
10.16.1 Output Value range control (S
FX Series Programmable Controllers
The following parameter table gives the additional parameters available with FX
These are:
For the full list of other parameters refer to page 5-102.
Note: S
into the data registers S3+22 and S3+23.
Bit 5 of parameter S
the output value (MV).
This feature restricts the output value to the specified limits; in effect, this automatically
performs the same operation as that described in section 10.15.1.
S
S
S
Param-
S
3
3
3
eter
- S
- S
- S
- S
+1
+22
+23
3
+ P
3
3
3
3
3
+1 bit 4: Pre-tuning operation flag.
+1 bit 5: Output Value range limit flag.
+22: Output Value upper limit.
+23: Output Value lower limit.
+1 b2 and b5 should not be active at the same time. Only one value each is entered
Action-reac-
tion
direction and
alarm control
Output Value,
maximum
positive
change alarm
Output Value,
Upper limit
restriction
Output Value,
maximum
negative
change alarm
Output Value,
Lower limit
restriction
name/func-
Parameter
tion
3
+1, when ON, activates S
Active
when
S
is set ON.
Active
when
S
is set ON.
Active
when
S
is set ON.
Active
when
S
is set ON.
3
3
3
3
b6-15
+1, b2
+1, b5
+1, b2
+1, b5
b0
b1
b2
b3
b4
b5
3
+1 b5)
Forward operation(0),
Reverse operation (1)
Process Value ( S
Output Value ( MV ) change alarm OFF(0)/ON(1)
Reserved
Activate pre-tuning (auto resets on completion)
Output Value (MV) range limit OFF(0)/ON(1)
Reserved
This is an alarm for the quantity of positive change
which can occur in one PID scan. If the Output
Value (MV) exceeds this value, bit S
set
This is an upper limit for the Output Value (MV) .
During operation the PID instruction restricts the
output so that it does not exceed this limit.
This is an alarm for the quantity of negative
change which can occur in one PID scan. If the
Output Value (MV) falls below this value, bit
S
This is a lower limit for the Output
Value (MV) .
During operation, the PID instruction restricts the
output so that it does not fall below this limit.
3
+24, b3 is set.
3
Description
+22 and S
2
) change alarm OFF(0)/ON(1)
3
+23 to be upper and lower limits for
3
+24, b2 is
Points Of Technique 10
10-26
2N(C)
0 to 32767
0 to 32767
applicable
-32768 to
-32768 to
Setting
MPUs.
32767
32767
range
Not