Specifications of FX1S-30MR-ES/UL

No. Of Analogue Inputs
16
No. Of Analogue Outputs
14
Ip/nema Rating
IP10
Approval Bodies
CE, CUL, UL
External Depth
49mm
External Length / Height
90mm
External Width
60mm
Mounting Type
Panel
2.9
FX Series Programmable Controllers
And Pulse, And Trailing Pulse
Program example:
Basic points to remember:
ANP
(ANd Pulse)
ANF
(ANd Falling
pulse)
- Use the ANDP and ANDF instructions for the serial connection of pulse contacts.
- Usage is the same as for AND and ANI; see earlier.
- ANP is active for one program scan after the associated device switches from OFF to
- ANF is active for one program scan after the associated device switches from ON to
Single operation flags M2800 to M3071:
Mnemonic
ON.
OFF.
• When used with flags M2800 to M3071 only the first instruction will activate. For
details see page 2-8
M40
X0
X1
Serial connection
of Rising edge
pulse
Serial connection
of Falling /
trailing edge
pulse
Function
T10
C0
ANF
ANP
Format
X, Y, M, S, T, C
X, Y, M, S, T, C
Devices
0
1
2
4
5
6
8
Basic Program Instructions 2
LD
OR
ANP
OUT
LDF
ANF
OUT
Program steps
M 40
X
T
M 100
X
C
Y
2-9
2
2
10
1
0
0
4