FX1S-30MR-ES/UL MITSUBISHI, FX1S-30MR-ES/UL Datasheet - Page 289

PLC, 16 IN, 14 RELAY OUT, 110V/2

FX1S-30MR-ES/UL

Manufacturer Part Number
FX1S-30MR-ES/UL
Description
PLC, 16 IN, 14 RELAY OUT, 110V/2
Manufacturer
MITSUBISHI
Datasheet

Specifications of FX1S-30MR-ES/UL

No. Of Analogue Inputs
16
No. Of Analogue Outputs
14
Ip/nema Rating
IP10
Approval Bodies
CE, CUL, UL
External Depth
49mm
External Length / Height
90mm
External Width
60mm
Mounting Type
Panel
6.11
FX Series Programmable Controller
High Speed Zone Compare
Table Comparison Flags
(M8130 to M8139 and D8130 to D8139)
For symbol key see page 6-1
M8130
M8131 ( )( )
M8132
M8133 ( )( )
M8134-
M8139
Diagnostic
Device
Selects comparison tables
to be used with the HSZ
instruction
Identifies when the HSZ
comparison table has been
processed.
Selects the use of the PLSY
instruction with the HSZ
comparison tables
Identifies when the HSZ
comparison table (when
used with the PLSY instruc-
tion) has been processed.
Reserved
Operation
D8130 ( )( )
D8131 ( )( )
D8132 ( )( )
D8133
D8134
D8135
( ) ( )
D8136
D8137
( ) ( )
D8138 -
D8139
D8140
D8141
( ) ( )
D8142
D8143
( ) ( )
Diagnostic
Device
Reserved
Contains the number of the
current record being pro-
cessed in the HSZ compari-
son table
Contains the number of the
current record being pro-
cessed in the HSZ compari-
son table when the PLSY
operation has been enabled
Contains the source (output
pulse frequency) data for the
PLSY instruction when used
with the HSZ comparison
table
Contains a copy of the value
for the current comparison
when the HSZ comparison
table and combined PLSY out-
put are used. This data is only
available in 32 bit or double
word format.
Contains the total number of
pulses that have been output
using the PLSY (or PLSR)
instruction. This data is only
available in 32 bit or double
word format
Reserved
Contains the total number of
pulses that have been output
to Y0 using the PLSY or PLSR
instructions. This data is only
available in 32 bit or double
word format.
Contains the total number of
pulses that have been output
to Y1 using the PLSY or PLSR
instructions. This data is only
available in 32 bit or double
word format.
Operation
Diagnostic Devices 6
6-11

Related parts for FX1S-30MR-ES/UL