WI.232FHSS-25-R/ WI.232FHSS-250-R DATASHEET
Tables 19, AutoAddress Register Settings
Default My GUID[3]: 0xFF
This is the most significant byte of the 32-bit factory-programmed, read-only MAC/GUID address. The
complete MyGUID address is unique amongst Wi.232 modules. The MyGUID[3-0] unique address is used
by all packet types as a unique origination address. This register is used in conjunction with My GUID[2-0]
registers to make up the module’s 32-bit source GUID. For more information on the operation of
addressing modes, please refer to the
Default My GUID[2]: 0xFF
This is byte 2 of the 32-bit factory-programmed, read-only MAC/GUID address. The complete MyGUID
address is unique amongst Wi.232 modules. The MyGUID[3-0] unique address is used by all packet types
as a unique origination address. This register is used in conjunction with My GUID[3] and My GUID[1-0]
registers to make up the module’s 32-bit source GUID. For more information on the operation of
addressing modes, please refer to the
0x00
0x04
0x06
0x07
0x0F
0x01-0x03,
0x05, 0x08-
0x0E
R
D7
7
R
D7
7
Auto Address
4.1.35. My GUID[3] (regMYGUID[3])
4.1.36. My GUID[2] (regMYGUID[2])
Mode
regMYGUID[3] (0x34)
regMYGUID[2] (0x35)
R
D6
6
R
D6
6
Auto Address Mode disabled
MAC Auto Address Mode
User Auto Address Mode
Extended User Auto Address Mode
Any Auto Address Mode
Undefined
R
D5
5
R
D5
5
Meaning
Addressing Modes
Addressing Modes
R
D4
4
R
D4
4
49
Destination Registers not populated
Auto-populates MAC Address Destination Register Only
Auto-populates User Address Destination Register
Auto-populates User Address Destination Register
Auto-populates MAC Address Destination Register
Undefined
R
D3
3
R
D3
3
section of this document.
section of this document.