Specifications of SPBT2532C2.AT

Frequency
2.4GHz
Data Rate - Maximum
2Mbps
Modulation Or Protocol
Bluetooth v2.1+EDR, Class 2 & 3
Applications
General Purpose
Power - Output
2dBm
Sensitivity
-85dBm
Voltage - Supply
2.8 V ~ 3.6 V
Data Interface
PCB, Surface Mount
Memory Size
256kB Flash, 48kB RAM
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Wireless Frequency
2400 MHz to 2483.5 MHz
Interface Type
I2C, I2S, SPI, UART
Data Rate
2 Mbps
Modulation
AFH
Operating Voltage
2.8 V to 3.6 V
Antenna
Without Antenna
Board Size
10 mm x 13 mm
Operating Temperature Range
- 40 C to + 85 C
Output Power
4 mA
Security
128 bit Encryption
Technology/ Type
Class 2 Bluetooth Module
Processor Series
STLC2500
For Use With
497-10656 - BOARD DEMO BLUETOOTH SPBT2532C2
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Transmitting
-
Current - Receiving
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
Bluetooth Devices
Other names
497-10539

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SPBT2532C2.AT
Manufacturer:
ST
0
Part Number:
SPBT2532C2.AT2
Manufacturer:
Broadchip
Quantity:
16 000
Part Number:
SPBT2532C2.AT2
Manufacturer:
ST
0
Other responses
Appendix F
F.1
F.2
F.3
46/50
The following subsections describe the 4 types of responses that occur under specific
circumstances, not necessarily as a result of a specific command. They are:
Reset
Upon either hardware reset or software reset (such as the Reset command), abSerial will
respond as follows after the reset is complete:
AT-AB -CommandMode-
AT-AB BDAddress [BD addr]
Because the BD address of the local device is reported during this response, the response
is different than a response to the Escape Sequence.
Escape sequence
If the Escape sequence, ^#^$^%, is received and no connection is active, abSerial will
immediately respond with:
AT-AB -CommandMode-
When the Escape Sequence is received while a connection is still active and there is no
data for 2 seconds, abSerial will respond (after those 2 seconds of no data) with the same
string.
abSerial will now be in command mode.
Controlled disconnect
If the local host initiates a disconnect, it must first put the abSerial interface into command
mode (see the section on Escape Sequence directly above). After a successful disconnect
command, the following response is made:
AT-AB ConnectionDown
Reset
Escape sequence
Controlled disconnect
Unexpected disconnect
Other responses
Doc ID 16089 Rev 7
SPBT2532C2.AT