SPBT2532C2.AT STMicroelectronics, SPBT2532C2.AT Datasheet - Page 42

IC BLUETOOTH VER 2.1 CLASS 2

SPBT2532C2.AT

Manufacturer Part Number
SPBT2532C2.AT
Description
IC BLUETOOTH VER 2.1 CLASS 2
Manufacturer
STMicroelectronics

Specifications of SPBT2532C2.AT

Frequency
2.4GHz
Data Rate - Maximum
2Mbps
Modulation Or Protocol
Bluetooth v2.1+EDR, Class 2 & 3
Applications
General Purpose
Power - Output
2dBm
Sensitivity
-85dBm
Voltage - Supply
2.8 V ~ 3.6 V
Data Interface
PCB, Surface Mount
Memory Size
256kB Flash, 48kB RAM
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Wireless Frequency
2400 MHz to 2483.5 MHz
Interface Type
I2C, I2S, SPI, UART
Data Rate
2 Mbps
Modulation
AFH
Operating Voltage
2.8 V to 3.6 V
Antenna
Without Antenna
Board Size
10 mm x 13 mm
Operating Temperature Range
- 40 C to + 85 C
Output Power
4 mA
Security
128 bit Encryption
Technology/ Type
Class 2 Bluetooth Module
Processor Series
STLC2500
For Use With
497-10656 - BOARD DEMO BLUETOOTH SPBT2532C2
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Transmitting
-
Current - Receiving
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
Bluetooth Devices
Other names
497-10539

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SPBT2532C2.AT
Manufacturer:
ST
0
Part Number:
SPBT2532C2.AT2
Manufacturer:
Broadchip
Quantity:
16 000
Part Number:
SPBT2532C2.AT2
Manufacturer:
ST
0
Error responses
E.3
E.4
42/50
ErrFormat
The ErrFormat error response will be sent if abSerial receives a command (text terminated
by a carriage return or line feed) that does not match the expected format of starting with
AT+AB .
Examples of commands that produce this error response are given in the following table.
Table 13.
ErrInvalidParam
The ErrInvalidParam error response will be sent if the parameters for the requested
command are not correct. The parameter(s) will be echoed back to the user starting from
the parameter that was rejected.
Examples of commands that produce this error response are given in the following table.
Table 14.
00043e008136 GOEP
12345678901234567
AT+AB ChangeBaud
AT+AB SPPConnect
AT+AB SPPConnect
AT+AB EnableBond
00043e000000
SPPConnect 00043e000000
Example
8136
1600
AT-AB Discovery
Example commands that generate <ErrFormat>
Example commands that generate <ErrInvalidParam>
Example
abcdef
AT-AB ErrInvalidParam 8136
AT-AB ErrInvalidParam goep
AT-AB ErrInvalidParam 1600
AT-AB ErrInvalidParam
12345678901234567
Response
Doc ID 16089 Rev 7
A valid command name that does not start with the right
prefix.
A command does not start with AT+AB
A command does not start with AT+AB
Numeric parameter not specified with required
number of digits (BD address must always be
12 hex characters).
Unrecognized (or unsupported) symbolic
parameter used.
Numeric parameter is out of range (specified
baud rate is not supported by command).
String parameter (PIN)has too many
characters.
Reason
Reason
SPBT2532C2.AT

Related parts for SPBT2532C2.AT