SPBT2532C2.AT STMicroelectronics, SPBT2532C2.AT Datasheet - Page 39

IC BLUETOOTH VER 2.1 CLASS 2

SPBT2532C2.AT

Manufacturer Part Number
SPBT2532C2.AT
Description
IC BLUETOOTH VER 2.1 CLASS 2
Manufacturer
STMicroelectronics

Specifications of SPBT2532C2.AT

Frequency
2.4GHz
Data Rate - Maximum
2Mbps
Modulation Or Protocol
Bluetooth v2.1+EDR, Class 2 & 3
Applications
General Purpose
Power - Output
2dBm
Sensitivity
-85dBm
Voltage - Supply
2.8 V ~ 3.6 V
Data Interface
PCB, Surface Mount
Memory Size
256kB Flash, 48kB RAM
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Wireless Frequency
2400 MHz to 2483.5 MHz
Interface Type
I2C, I2S, SPI, UART
Data Rate
2 Mbps
Modulation
AFH
Operating Voltage
2.8 V to 3.6 V
Antenna
Without Antenna
Board Size
10 mm x 13 mm
Operating Temperature Range
- 40 C to + 85 C
Output Power
4 mA
Security
128 bit Encryption
Technology/ Type
Class 2 Bluetooth Module
Processor Series
STLC2500
For Use With
497-10656 - BOARD DEMO BLUETOOTH SPBT2532C2
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Transmitting
-
Current - Receiving
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
Bluetooth Devices
Other names
497-10539

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SPBT2532C2.AT
Manufacturer:
ST
0
Part Number:
SPBT2532C2.AT2
Manufacturer:
Broadchip
Quantity:
16 000
Part Number:
SPBT2532C2.AT2
Manufacturer:
ST
0
SPBT2532C2.AT
D.29
D.29.1
D.29.2
D.29.3
D.30
D.30.1
D.30.2
StreamingSerial
The StreamingSerial command is used to enable/disable the UART flow control.
Syntax
AT+AB StreamingSerial [Enable/Disable]
Where [Enable/Disable] is an e or E character to enable this parameter and a d or D
character to disable it. StreamingSerial command will disable RTS/CTS hardware flow
control and discard non-transmitted data when enabled. RTS/CTS flow control is enabled,
when StreamingSerial is disabled.
Query
An alternative syntax may be used to query the current StreamingSerial feature status. This
syntax is not supported by other commands.
AT+AB StreamingSerial
Responses
If the feature is successfully applied or queried, the response is:
AT-AB StreamingSerial [Enabled/Disabled]
UpdateInquiryScan
The UpdateInquiryScan command is used to modify the Inquiry scan parameters: mode,
duration, and interval.
Syntax
AT+AB UpdateInquiryScan [mode] [duration] [interval]
where[mode] is the discoverable mode:
[duration] is the scan length in slots; 18 to 4096. The default duration is 18 slots.
[interval] is the period between scans in slots; 18 to 4096. The default interval is 2048
slots
Responses
If the command is successful, the response is:
AT-AB InquiryScanUpdateDone
0: non-discoverable
1: limited discoverability – not supported
2: discoverable
Doc ID 16089 Rev 7