AT32UC3B0512-Z2UR Atmel, AT32UC3B0512-Z2UR Datasheet - Page 306

IC MCU AVR32 512K FLASH 64QFN

AT32UC3B0512-Z2UR

Manufacturer Part Number
AT32UC3B0512-Z2UR
Description
IC MCU AVR32 512K FLASH 64QFN
Manufacturer
Atmel
Series
AVR®32 UC3r
Datasheet

Specifications of AT32UC3B0512-Z2UR

Package / Case
64-QFN
Voltage - Supply (vcc/vdd)
1.65 V ~ 1.95 V
Operating Temperature
-40°C ~ 85°C
Speed
60MHz
Number Of I /o
44
Core Processor
AVR
Program Memory Type
FLASH
Ram Size
96K x 8
Program Memory Size
512KB (512K x 8)
Data Converters
A/D 8x10b
Oscillator Type
Internal
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Connectivity
I²C, IrDA, SPI, SSC, UART/USART, USB
Core Size
32-Bit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3B0512-Z2UR
Manufacturer:
ATMEL
Quantity:
2 010
21.6.1.2
Table 21-3.
21.6.1.3
32059J–12/2010
Source Clock
12 000 000
12 288 000
14 318 180
14 745 600
18 432 000
24 000 000
24 576 000
25 000 000
32 000 000
32 768 000
33 000 000
40 000 000
50 000 000
60 000 000
3 686 400
4 915 200
5 000 000
7 372 800
8 000 000
MHz
Baud Rate Calculation Example
Fractional Baud Rate in Asynchronous Mode
Baud Rate Example (OVER = 0)
Expected Baud
Table 21-3
clock frequencies. This table also shows the actual resulting baud rate and the error.
The baud rate is calculated with the following formula:
The baud rate error is calculated with the following formula. It is not recommended to work with
an error higher than 5%.
The Baud Rate generator previously defined is subject to the following limitation: the output fre-
quency changes by only integer multiples of the reference frequency. An approach to this
problem is to integrate a fractional N clock generator that has a high resolution. The generator
architecture is modified to obtain Baud Rate changes by a fraction of the reference source clock.
This fractional part is programmed with the FP field in the Baud Rate Generator Register
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
Rate
Bit/s
Error
BaudRate
shows calculations of CD to obtain a baud rate at 38400 bauds for different source
=
1
Calculation Result
ExpectedBaudRate
-------------------------------------------------- -
ActualBaudRate
=
(
12.00
13.02
19.53
20.00
23.30
24.00
30.00
39.06
40.00
40.69
52.08
53.33
53.71
65.10
81.38
97.66
6.00
8.00
8.14
CLKUSART
)
(
CD
CD
12
13
20
20
23
24
30
39
40
40
52
53
54
65
81
98
×
6
8
8
16
)
Actual Baud Rate
38 400.00
38 400.00
39 062.50
38 400.00
38 461.54
37 500.00
38 400.00
38 908.10
38 400.00
38 400.00
38 461.54
38 400.00
38 109.76
38 461.54
38 641.51
38 194.44
38 461.54
38 580.25
38 265.31
Bit/s
AT32UC3B
0.00%
0.00%
1.70%
0.00%
0.16%
2.40%
0.00%
1.31%
0.00%
0.00%
0.16%
0.00%
0.76%
0.16%
0.63%
0.54%
0.16%
0.47%
0.35%
Error
306

Related parts for AT32UC3B0512-Z2UR