EP9315-CB Cirrus Logic Inc, EP9315-CB Datasheet - Page 705

IC ARM920T MCU 200MHZ 352-PBGA

EP9315-CB

Manufacturer Part Number
EP9315-CB
Description
IC ARM920T MCU 200MHZ 352-PBGA
Manufacturer
Cirrus Logic Inc
Series
EP9r
Datasheets

Specifications of EP9315-CB

Core Processor
ARM9
Core Size
16/32-Bit
Speed
200MHz
Connectivity
EBI/EMI, EIDE, Ethernet, I²C, IrDA, Keypad/Touchscreen, PCMCIA, SPI, UART/USART, USB
Peripherals
AC'97, DMA, I&sup2:S, LCD, LED, MaverickKey, POR, PWM, WDT
Number Of I /o
16
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 3.6 V
Data Converters
A/D 8x12b
Oscillator Type
External
Operating Temperature
0°C ~ 70°C
Package / Case
352-BGA
Processor Series
EP93xx
Core
ARM920T
Data Bus Width
32 bit
3rd Party Development Tools
MDK-ARM, RL-ARM, ULINK2
Development Tools By Supplier
EDB9315A-Z
For Use With
598-1144 - KIT DEVELOPMENT EP9315 ARM9
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Lead Free Status / Rohs Status
No
Other names
598-1261

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP9315-CB
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
EP9315-CB
Manufacturer:
ALTERA
0
Part Number:
EP9315-CBZ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
EP9315-CBZ
Manufacturer:
ALTERA
0
Part Number:
EP9315-CBZ
Manufacturer:
CIRRUS
Quantity:
20 000
Company:
Part Number:
EP9315-CBZ
Quantity:
48
AC97S12Data
DS785UM1
31
15
Bit Descriptions:
Address:
Definition:
Bit Descriptions:
30
14
29
13
28
12
codec, the AC97S2Data register must be written to before the AC97S1Data
register is written.
If a power down is required, then the software must write to SLOT1TX location
address 0x26, which is recorded by the controller. If the AC97S2Data bit 12 is
set, then the controller will go into power down mode.
RSVD:
DATA:
0x8088_0088 - Read/Write
Slot 12 Data Register. The AC97S12Data register is a read / write register.
Data written to it will be sent on the next available frame in SLOT 12. When
this register is read, the data contained within it is the data that was last
received for SLOT 12.
RSVD:
DATA:
27
11
26
10
RSVD
Copyright 2007 Cirrus Logic
25
9
Reserved. Unknown During Read.
Read operation: Read data value of the last value written
to this register via the AC-Link interface.
Write operation: Write data value to transmit on slot 2 on
next available frame. Once the data has been transmitted,
it will marked as invalid.
Reserved. Unknown During Read.
Read operation: Read data value of the last value received
in SLOT 12. Bit 0 is monitored to see if a GPIOINT has
occurred.
Write operation: Write data value to transmit on slot 12 on
next available frame. Once the data has been transmitted
it will marked as invalid.
24
8
DATA
23
7
22
6
21
5
20
4
19
3
EP93xx User’s Guide
18
2
AC’97 Controller
DATA
17
1
22-17
16
0
22