P87C591VFA/00,512 NXP Semiconductors, P87C591VFA/00,512 Datasheet - Page 86

IC 80C51 MCU 16K OTP 44-PLCC

P87C591VFA/00,512

Manufacturer Part Number
P87C591VFA/00,512
Description
IC 80C51 MCU 16K OTP 44-PLCC
Manufacturer
NXP Semiconductors
Series
87Cr
Datasheet

Specifications of P87C591VFA/00,512

Core Processor
8051
Core Size
8-Bit
Speed
12MHz
Connectivity
CAN, EBI/EMI, I²C, UART/USART
Peripherals
POR, PWM, WDT
Number Of I /o
32
Program Memory Size
16KB (16K x 8)
Program Memory Type
OTP
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
4.75 V ~ 5.25 V
Data Converters
A/D 6x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
44-PLCC
Processor Series
P87C5x
Core
80C51
Data Bus Width
8 bit
Data Ram Size
512 B
Interface Type
CAN, I2C, UART
Maximum Clock Frequency
12 MHz
Number Of Programmable I/os
32
Number Of Timers
3
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 6 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
568-1256-5
935268182512
P87C591VFAA

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P87C591VFA/00,512
Manufacturer:
TI
Quantity:
8
Part Number:
P87C591VFA/00,512
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Philips Semiconductors
master of the bus. In other words, if AA is reset, SIO0
cannot enter a slave mode. STA, STO, and SI must be
reset.
The master transmitter mode may now be entered by
setting the STA bit using the SETB instruction. The SIO1
logic will now test the I
condition as soon as the bus becomes free. When a
START condition is transmitted, the serial interrupt flag
(SI) is set, and the status code in the status register
(S1STA) will be 08H. This status code must be used to
vector to an interrupt service routine that loads S1DAT with
the slave address and the data direction bit (SLA+W). The
Table 58 Address Register S1CON (address D8H)
15.2.14.2 Master Receiver Mode
In the master receiver mode, a number of data bytes are
received from a slave transmitter (see Figure 38). The
transfer is initialized as in the master transmitter mode.
When the start condition has been transmitted, the
interrupt service routine must load S1DAT with the 7-bit
slave address and the data direction bit (SLA+R). The SI
bit in S1CON must then be cleared before the serial
transfer can continue.
When the slave address and the data direction bit have
been transmitted and an acknowledgment bit has been
received, the serial interrupt flag (SI) is set again, and a
number of status codes in S1STA are possible. These are
40H, 48H, or 38H for the master mode and also 68H, 78H,
or B0H if the slave mode was enabled (AA = logic 1). The
appropriate action to be taken for each of these status
codes is detailed in Table 62. ENS1, CR1, and CR0 are
not affected by the serial transfer and are not referred to in
Table 62. After a repeated start condition (state 10H),
SIO1 may switch to the master transmitter mode by
loading S1DAT with SLA+W.
15.2.14.3 Slave Receiver Mode:
In the slave receiver mode, a number of data bytes are
received from a master transmitter (see Figure 39). To
initiate the slave receiver mode, S1ADR and S1CON must
be loaded as in Table 59.
2000 Jul 26
Single-chip 8-bit microcontroller with CAN controller
bit rate
CR2
7
ENS1
6
1
2
C bus and generate a start
STA
5
0
STO
4
0
86
SI bit in S1CON must then be reset before the serial
transfer can continue.
When the slave address and the direction bit have been
transmitted and an acknowledgment bit has been
received, the serial interrupt flag (SI) is set again, and a
number of status codes in S1STA are possible. There are
18H, 20H, or 38H for the master mode and also 68H, 78H,
or B0H if the slave mode was enabled (AA = logic 1). The
appropriate action to be taken for each of these status
codes is detailed in Table 61. After a repeated start
condition (state 10H). SIO1 may switch to the master
receiver mode by loading S1DAT with SLA+R).
The upper 7 bits are the address to which SIO1 will
respond when addressed by a master. If the LSB (GC) is
set, SIO1 will respond to the general call address (00H);
otherwise it ignores the general call address.
CR0, CR1, and CR2 do not affect SIO1 in the slave mode.
ENS1 must be set to logic 1 to enable SIO1. The AA bit
must be set to enable SIO1 to acknowledge its own slave
address or the general call address. STA, STO, and SI
must be reset.
When S1ADR and S1CON have been initialized, SIO1
waits until it is addressed by its own slave address
followed by the data direction bit which must be “0” (W) for
SIO1 to operate in the slave receiver mode. After its own
slave address and the W bit have been received, the serial
interrupt flag (I) is set and a valid status code can be read
from S1STA. This status code is used to vector to an
interrupt service routine, and the appropriate action to be
taken for each of these status codes is detailed in
Table 63. The slave receiver mode may also be entered if
arbitration is lost while SIO1 is in the master mode (see
status 68H and 78H).
If the AA bit is reset during a transfer, SIO1 will return a not
acknowledge (logic 1) to SDA after the next received data
byte. While AA is reset, SIO1 does not respond to its own
slave address or a general call address. However, the I
bus is still monitored and address recognition may be
resumed at any time by setting AA. This means that the AA
bit may be used to temporarily isolate SIO1 from the I
bus.
SI
3
0
AA
X
2
Preliminary Specification
CR1
1
bit rate
P8xC591
CR0
0
2
C
2
C

Related parts for P87C591VFA/00,512