6.3.5 Link Pulse Timing Characteristics
Table 6.10
t61
t62
t63
t64
t65
t66
t67
t68
t69
t70
t71
t72
Sym
NLP Transmit Link Pulse
Width
NLP Transmit Link Pulse
Period
NLP Receive Link Pulse
Width Required for Detection
NLP Receive Link Pulse
Minimum Period Required
for Detection
NLP Receive Link Pulse
Maximum Period Required
for Detection
NLP Receive Link Pulses
Required to Exit Link Fail
State
FLP Transmit Link Pulse
Width
FLP Transmit Clock Pulse to
Data Pulse Period
FLP Transmit Clock Pulse to
Clock Pulse Period
FLP Transmit Link Pulse
Burst Period
FLP Receive Link Pulse
Width Required for Detection
FLP Receive Link Pulse
Minimum Period Required
for Clock Pulse Detection
Link Pulse Timing
Parameter
Table 6.10
and
AC Electrical Characteristics
Figure 6.15
shows the Link Pulse AC timing parameters. See
for the Link Pulse timing diagrams.
Copyright © 2000, 2001, 2002 by LSI Logic Corporation. All rights reserved.
55.5
Min
100
111
50
50
50
8
6
3
8
5
See
Limit
Figure 2.7
62.5
Typ
125
3
Max
69.5
150
150
139
24
22
25
7
3
Pulses
Unit
Link
ms
ms
ms
ms
ms
ms
ms
ns
ns
ns
ns
link_test_min
link_test_max
lc_max
interval_timer
transmit_link_burst
_timer
flp_test_min_timer
Condition
Figure 6.14
6-19

Related parts for L80227