PIC18F85K22-I/PT Microchip Technology, PIC18F85K22-I/PT Datasheet - Page 398

no-image

PIC18F85K22-I/PT

Manufacturer Part Number
PIC18F85K22-I/PT
Description
IC, 8BIT MCU, PIC18F, 64MHZ, TQFP-80
Manufacturer
Microchip Technology
Series
PIC® XLP™ 18Fr
Datasheet

Specifications of PIC18F85K22-I/PT

Controller Family/series
PIC18
No. Of I/o's
69
Eeprom Memory Size
1KB
Ram Memory Size
2KB
Cpu Speed
64MHz
No. Of Timers
8
Core Size
8 Bit
Program Memory Size
32KB
Core Processor
PIC
Speed
64MHz
Connectivity
EBI/EMI, I²C, LIN, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, LVD, POR, PWM, WDT
Number Of I /o
69
Program Memory Type
FLASH
Eeprom Size
1K x 8
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 24x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
80-TQFP
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18F85K22-I/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
PIC18F85K22-I/PT
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
PIC18F85K22-I/PTRSL
Manufacturer:
Microchip Technology
Quantity:
10 000
PIC18F87K22 FAMILY
27.6
Time can be precisely measured after the ratio ( C/I ) is
measured from the current and capacitance calibration
step. To do that:
1.
2.
3.
4.
5.
FIGURE 27-3:
DS39960D-page 398
Initialize the A/D Converter and the CTMU.
Set EDG1STAT.
Set EDG2STAT.
Perform an A/D conversion.
Calculate the time between edges as T = (C/I) * V ,
where:
• I is calculated in the current calibration
• C is calculated in the capacitance calibra-
• V is measured by performing the A/D conversion
step (
Calibration”
tion step (
Calibration”
Measuring Time with the CTMU
Module
Section 27.4.1 “Current Source
Section 27.4.2 “Capacitance
)
)
TYPICAL CONNECTIONS AND INTERNAL CONFIGURATION FOR TIME
MEASUREMENT
CTED1
CTED2
AN
R
PR
X
EDG1
EDG2
It is assumed that the time measured is small enough
that the capacitance, C
to the A/D Converter. For the smallest time measure-
ment, always set the A/D Channel Select register
(AD1CHS) to an unused A/D channel, the correspond-
ing pin for which is not connected to any circuit board
trace. This minimizes added stray capacitance, keep-
ing the total circuit capacitance close to that of the A/D
Converter itself (25 pF).
To measure longer time intervals, an external capacitor
may be connected to an A/D channel and that channel
selected whenever making a time measurement.
C
AD
A/D Converter
PIC18F87K22
Current Source
CTMU
Output Pulse
 2009-2011 Microchip Technology Inc.
OFFSET
, provides a valid voltage