866 B&K Precision, 866 Datasheet - Page 119

PROGRAMMER UNIV W/ USB INTERFACE

866

Manufacturer Part Number
866
Description
PROGRAMMER UNIV W/ USB INTERFACE
Manufacturer
B&K Precision
Type
Universalr
Datasheets

Specifications of 866

Contents
Programmer, Adapter, Cable, Manual and Software
For Use With/related Products
EPROM, EEPROM-Flash, Serial EPROM, Microcontroller & PLD
Other names
866BK
Q2005647

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
866
Quantity:
2 950
Part Number:
866+++
Quantity:
1 480
Part Number:
866590-0950
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
8669-001
Manufacturer:
TOSHIBA
Quantity:
6 222
Part Number:
866B509
Manufacturer:
BOM
Quantity:
894
Device / Device options / Serialization
1. Ignore not programmed serial values
2. Add not programmed serial values to file
Serialization is special mode of program. When a serialization
mode is activated, a specified value is automatically inserted
on predefined address into buffer before programming each
device. When more devices are programmed one by one, the
serial number value is changed for each device automatically
and inserted into buffer before programming device, so each
device has unique serial number.
There are two types of serialization:
If a new device is selected, the serialization function is set to a
default state i.e. disabled.
Actual serialization settings for actually selected device are
saving to disk along with associated device by File / Exit and
save command.
When incremental mode is active following actual settings are
saved to configuration file: address, size, serial value,
incremental step and settings of modes ASCII / BIN, DEC /
HEX, LS byte / MS Byte first.
When from-file mode is active following actual settings are
saved to configuration file: name of input serialization file and
actual label, which indicates the line with actual serial number
in input file.
When program is in multiprogramming mode (multiple socket
programmer is actually selected) the special section - Action
on not programmed serial values due to error - is displayed
in dialog Serialization. In this section two choices are
available:
Inactive level of ISP signals - this parameter determine
level of ISP signals after finishing access to target device.
Signals of ISP connector can be set to Pull-up (signals are
tied through 22k resistors to supply voltage) or Pull-down
(signals are tied through 22k resistors to ground).
Keep ISP signals at defined level after operation - enables
keeping set level of ISP signals after access to target device
finished. Control program indicates activated pull-up/pull-
down resistors by displaying window with warning. After user
close this window control program will deactivate resistors.
Incremental mode