1604A B&K Precision, 1604A Datasheet

BK Precision Isolation Transformer, Isolation Leakage:

1604A

Manufacturer Part Number
1604A
Description
BK Precision Isolation Transformer, Isolation Leakage:
Manufacturer
B&K Precision
Datasheet

Specifications of 1604A

Output Current (channel 1)
2 A
Output Voltage (channel 1)
117 VAC to 124 VAC
Input Voltage
120 VAC
Number Of Outputs
1
Output Voltage (1)
117 VAC to 124 VAC
Output Current (1)
2 A
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Model 1653A
Variable Isolated AC Power Supply. Model 1653A is a compact,
rugged unit.
Model 1655A
Variable Isolated AC Power Supply. Model 1655A displays V, A,
VA and leakage.
Model 1604A
Isolation Transformer-Use Model 1604A for safe testing of
transformerless equipment.
Specifications
Variable isolated 0-150 VAC
2 A continuous output
Displays voltage or current readings
Isolation transformer to eliminate shock
hazard while servicing “hot chassis” equipment
Variable-isolated output—0-150VAC
3 A continuous, 4 A intermittent output
Built-in soldering iron temperature control
Expanded leakage scale
Circuit breaker overload protection
Displays V, A,VA, leakage
Leakage: less than 0.1 mA
Output Voltage: 117-124 V nominal
(120 V input)
Output Current: 1.25 A continuous
18
Isolation
Output Voltage
Output Current
Power Requirements
Operating Temperature 32˚ to 104˚F (0° to +40°C)
Dimensions (HxWxD)
Weight
One Year Warranty
leakage less than 0.1 mA
117-124 V nominal (120 V input)
1.25 A continuous
( 2A intermittent)
120 VAC, 60 Hz, 175W
4 x 4 x 5.5" (100 x 100 x 140 mm)
6 lbs. (2.7 kg.)
1655A
1604A
model
Specifications
Input Requirements 105-130 VAC, 60 Hz.
OUTPUT POWER RATING
Direct
CONNECTIONS
Direct
Isolated
GENERAL
Regulation
Isolation
Dimensions
Weight
*Output voltages rated w/input at 120 volts.
Voltage Adjustment Rage
Output Isolation
Current Range
Maximum Current (Isolated)
Peak Current (inrush)
Voltage/Current Sensing
Meter Scale
Leakage
Metering
Meter Accuracy
Soldering Iron Temp. Control
Power Requirements
Dimensions
(HxWxD)
Weight
(HxWxD)
Specifications
500 VA continuous. Isolated: 350 VA
continuous, 500 VA intermittent.
Duplex outlet (3-conductor).
Duplex outlet (3-conductor).
No load (350 VA), voltage change<4%.
Complies—UL standard 1012, May 1977.
5.1 x 5.5 x 8" (130 x 140 x 200 mm)
11 lbs. (5 kg)
TR-110
One Year Warranty
TR-110
5.5 x 6.5 x 10.5"
0 - 2A
2A continuous (0-130V)
N/A
0-140 VAC
0-2 VAC
3 1/2" overrange protected
±5% of full scale
120 VAC ±10%, 60 Hz
300VA
(140 x 165 x 267 mm)
12 lbs. (5.5 kg)
Leakage less than 0.1mA (25°C, 50% RH)
Sine wave average, calibrated in RMS
model
1653A
0-150 VAC with input at 120VAC
Model TR-110
Dual Output Isolation - Use Model TR-110
for safe testing of transformerless equipment.
Direct: Convenience duplex outlet
provides line voltage for auxiliary
equipment up to 500 VA
Isolated:Two 3-position slide
switches provide 9 combinations
of voltage selection from 90 to
140 V*, up to 350 VA continuous
or 500 VA intermittent. Self-
contained power switch with
pilot lamp.
0 - 3A
3A continuous, 4A intermittent (0-130V)
30A max.
(inrush limited to one cycle at30A)
0 - 240VAC
0- 480VAC (voltage set at 120)
0 - 5000 µA
(expanded in 100 - 500 µA portion,
compressed to 5mA full scale)
4 1/2 multicolor scales, overrange protected
±5% of full scale(volts andcurrent)
±5% at 500µA(leakage)
70 - 99% of power line (100W max.)
120 VAC ±10%, 60 Hz
600VA at Maximum Output
10.5 x 5.7 x 12"
(267 x 145 x 305 mm)
22 lbs. (10 kg )
One Year Warranty
1604A
1655A
1653A
models

Related parts for 1604A

Related keywords