HS7046EPH60H Renesas Electronics America, HS7046EPH60H Datasheet - Page 32

no-image

HS7046EPH60H

Manufacturer Part Number
HS7046EPH60H
Description
DEV EMULATOR BASE SH7046
Manufacturer
Renesas Electronics America
Series
SuperH®r
Type
Microcontrollerr
Datasheet

Specifications of HS7046EPH60H

Contents
E6000 Emulator and CD-ROM
For Use With/related Products
SH7046
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
2.2
2.2.1
1. Check that the emulator power switch is turned off. Ensure that the power lamp on the right side of the
2. Remove the AC power cable of the E6000H station from the outlet (if the cable is connected to the outlet).
3. Connect pin 1 on the user system connector to the connector installed at the bottom of the E6000H user
10
E6000H station's front panel is not lit.
system interface board. When connecting the connector, prevent the upper or lower side of the board from
lifting off the connector. Alternately tighten the screws on both sides of the board.
connecting or disconnecting any CABLES. Failure to do so will result
in a FIRE HAZARD and will damage the user system and the emulator
or will result in PERSONAL INJURY. The USER PROGRAM will be
LOST.
Connecting the User System
Emulator Connection
Always switch OFF the emulator and user system before
WARNING

Related parts for HS7046EPH60H