HS7046EPH60H Renesas Electronics America, HS7046EPH60H Datasheet - Page 157

no-image

HS7046EPH60H

Manufacturer Part Number
HS7046EPH60H
Description
DEV EMULATOR BASE SH7046
Manufacturer
Renesas Electronics America
Series
SuperH®r
Type
Microcontrollerr
Datasheet

Specifications of HS7046EPH60H

Contents
E6000 Emulator and CD-ROM
For Use With/related Products
SH7046
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3.9.2
Conditions for measurement can be displayed and changed in the [Performance Analysis] window. Select a point
where a condition is to be set, and then select [Set…] from the popup menu to display the [Performance Analysis
Properties] dialog box.
Select either from the following five modes as the condition by the [Measurement Method] option:
Table 3.3
Set a condition for measurement according to the mode being selected. The parameters to be set depend on the
modes.
The [Performance Analysis Properties] window has a support function to enter the address range of a function
automatically if the name of the function is entered to set an address range. Entering a function name in the
[Input Function Range] dialog box displayed by clicking the […] button on the [Performance Analysis
Properties] dialog box automatically enters the address range of the function.
Notes: 1. Entering the name of an overload function or a class opens the [Select Function] dialog box. Select a
[Measurement Method] Option
Time Of Specified Range Measurement
Start Point To End Point Measurement
Start Range To End Range Measurement
Access Count Of Specified Range Measurement
Called Count Of Specified Range Measurement
2. The addresses figured out are just for reference. In some cases, the end address of a function may be
Setting Conditions for Measurement
function in this dialog box.
different. Check the last instruction of the function in the [Disassembly] window to correct the value
set in [End Address] so that it will be the address of the last instruction (in general, the last instruction
of a function is a RTS instruction). A label name or an expression can be entered instead of an
address value in boxes where an address should be entered.
Conditions for Measurement (Measurement Method)
Figure 3.37 [Input Function Range] Window
69

Related parts for HS7046EPH60H