CYII5SC1300-EVAL Cypress Semiconductor Corp, CYII5SC1300-EVAL Datasheet - Page 12

BOARD EVAL IMG SENS IBIS5-B-1300

CYII5SC1300-EVAL

Manufacturer Part Number
CYII5SC1300-EVAL
Description
BOARD EVAL IMG SENS IBIS5-B-1300
Manufacturer
Cypress Semiconductor Corp
Datasheets

Specifications of CYII5SC1300-EVAL

Sensor Type
CMOS Imaging, Color (RGB)
Sensing Range
1.3 Megapixel
Interface
Parallel/Serial
Sensitivity
106 fps
Voltage - Supply
3 V ~ 4.5 V
Embedded
No
Utilized Ic / Part
IBIS5-B-1300
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Document #: 38-05710 Rev. *A
Table 10.Internal Registers
1 (0001)
2 (0010)
4 (0100)
5 (0101)
8 (1000)
3 (0011)
6 (0110)
7 (0111)
Register
0 (0000)
11:0
11:0
11:0
11:0
10:0
10:0
10:0
Bit
7:0
6:0
10
11
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
YL_REG
SEQUENCER register
SHUTTER_TYPE
FRAME_CAL_MODE
LINE_CAL_MODE
CONT_CHARGE
GRAN_X_SEQ_LSB
GRAN_X_SEQ_MSB
GRAN_SS_SEQ_LSB
GRAN_SS_SEQ_MSB
KNEEPOINT_LSB
KNEEPOINT_MSB
KNEEPOINT_ENABLE
VDDR_RIGHT_EXT
NROF_PIXELS
NROF_LINES
INT_TIME
X_REG
YR_REG
IMAGE CORE register
TEST_EVEN
TEST_ODD
X_SUBSAMPLE
X_SWAP12
X_SWAP30
Y_SUBSAMPLE
Y_SWAP12
Y_SWAP30
AMPLIFIER register
GAIN<0>
GAIN<1>
GAIN<2>
GAIN<3>
UNITY
DUAL_OUT
STANDBY
Name
Default value <11:0>: “000011000100”
1 = rolling shutter
0 = synchronous shutter
0 = fast
1 = slow
0 = fast
1 = slow
1 = “Continuous” precharge enabled.
Granularity of the X sequencer clock
Granularity of the SS sequencer clock
Sets reset voltage for multiple slope operation.
1 = Enables multiple slope operation in synchronous shutter mode
1 = Disables circuit that generates VDDR_RIGHT voltage so
external voltage can be applied.
Number of pixels to count (maximum 1280/2).
Default value <11:0>: “001001111111”
Number of lines to count.
Default value <11:0>: “001111111111”
Integration time.
Default value <11:0>: “111111111111”
X start position (maximum 1280/2).
Default value <10:0>: “00000000000”
Y-left start position.
Default value <10:0>: “00000000000”
Y-right start position.
Default value <10:0>: “00000000000”
Default value <7:0>: “00000000”
Test even columns.
Test odd columns.
Enable sub-sampling in X-direction.
Swap columns 1-2, 5-6, …
Swap columns 3-4, 7-8, …
Enable sub-sampling in Y-direction.
Swap rows 1-2, 5-6, …
Swap rows 3-4, 7-8, …
Default value <6:0>: “1010000”
Output amplifier gain setting.
1 = Amplifier in unity gain mode.
1 = Activates second output.
0 = Amplifier in standby mode.
Description
CYII5FM1300AB
IBIS5-B-1300
Page 12 of 42