Specifications of GP485A

Accessory Type
Controller
For Use With/related Products
ZUP Series
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q4846340
Specifications ZUP Series
*1: Minimum voltage is guaranteed to maximum 0.2 % of the rated output
*2: Minimum current is guaranteed to maximum 0.4 % of the rated output
*3: Time for recovery to within ±50 mV against current change of 50 %
*4: From zero volts to full scale, resistive load and current setting at
*5: From no load to full load, constant input voltage.
*6: From 85~132 V AC or 170~265 V AC constant load.
52
Model
Display
Output protections
Input
Environment
Mechanical
External control
Functions
Approvals
Conducted EMI
Radiated EMI
Series operation
Parallel operation
Cooling
Withstand options
Isolation resistance
voltage.
current.
maximum.
to 100 %.
Voltage
Current
Status
Input voltage (*11)
Input current (*12 )
Inrush current (100/200 V)
Efficiency (*12 )
Input current harmonics
Power factor (TYP)
Operating temperature
Operating humidity
Storage temperature
Operating humidity
Vibration
Shock
Weight
Size (WxHxD)
Output on/off
Output good
Output voltage programming
Output current programming
Remote sensing
Communication interface
Safety standards
EMC standards
*7: At cold start Ta=25 °C.
*8: Change in output over 8 hour interval constant line, load and ambient
*9: Given for control of the output via the serial communication or via front
*10: Inverter shut-down method, manual reset (OVP will shut-down output).
*11: For cases where conformance to various safety specs. (UL, IEC, etc.)
*12: At 100 V/200 V and Maximum Output Power.
temperature following 30-minutes warm-up.
panel controls.
are required, to be described as 100–240 V AC (50/60 Hz) on name
plate.
A
A
%
kg
mm
ZUP36-12
3 digits (6 V; 20 V; 36 V; 60 V; 80 V);
3.5 digits (10 V; 120 V) accuracy: 0.2 % ±2 digits
3.5 digits (132 A); All others 3 digits, accuracy: 0.5 % ±3 digits
CV/CC, Alarm, Fold, Local/Remote, On/Off
Over Voltage, Over Temperature, Foldback.
85 – 265 V AC Continuous, 47–63 Hz
5.6/2.7
15
80/84
Complies with EN61000-3-2, Class A
0.99 at 100/200 V AC, 100 % load.
0 to 50 °C ; 100 % Load
30-90 % RH (No dewdrop).
–20 to 70 °C
10 – 95 % RH (No dewdrop).
10–55 Hz, Amplitude (sweep 1 min) 2 g, X, Y, Z,
When mounted with mounting screws.
Less than 20 g
3.2
200 W and 400 W units: 70 x 124 x 350.
800 W units: 140 X 124 X 350 (Refer to outline drawing)
By TTL Signal or Dry Contact (Refer to instruction manual)
Open collector (Refer to instruction manual).
By Voltage (0– 4 V) or by Resistance (0–4 K)
(Refer to instruction manual).
By Voltage (0 – 4 V) or by Resistance (0–4 K)
(Refer to instruction manual).
Maximum 0.5 V drop on each load wire for model up to 60 V
and 2 V for the 80 V, 120 V models
RS232 and RS485 Built-in, IEEE488 Optional.
UL3111-1, EN61010-1
EN61326-1, IEC 61326-1, FCC part 15 (class A)
EN55022-B, FCC-B, VCCI-2
EN55022-A, FCC-A, VCCI-1
Up to 2 units (Refer to instruction manual).
Master/Slave method; up to 5 units (Refer to instruction manual)
Forced air by blower fan (Blower fan is mounted within unit)
Input – Chassis...2.0 kV AC 1 min, Input – Output...3.0 kV AC 1 min,
Output – GND...500 V AC 1 min.
More than 100 MΩ at 25 °C and 70 % R.H.
ZUP36-24
11.2/5.4
30
80/84
5.8
ZUP60-3.5
2.9/1.4
15/30 (*7)
75/79
2.9