GP485A TDK Corporation, GP485A Datasheet - Page 16

no-image

GP485A

Manufacturer Part Number
GP485A
Description
GPIB CONTROLLER
Manufacturer
TDK Corporation
Series
ZUPr
Datasheets

Specifications of GP485A

Accessory Type
Controller
For Use With/related Products
ZUP Series
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q4846340
Specifications Genesys™ GEN/GENH 750 W / 1500 W
16
1.4 Analog Programming and Monitoring
1. Vout Voltage Programming
2. Iout Voltage Programming
3. Vout Resistor Programming
4. Iout Resistor Programming
5. On/Off control (rear panel)
6. Output current monitor
7. Output voltage monitor
8. Power supply OK signal
9. CV/CC indicator
10. Enable/Disable
11. Local/Remote analog control
12. Local/Remote analog control indicator
1.5 Front Panel
1. Control functions
2. Display
3. Indications
1.6 Interface RS-232 & RS-485 or Optional GPIB / LAN Interface
Model
1. Remote Voltage Programming (16 bit)
Resolution (0.012 % of Vo Rated)
Accuracy (0.05 % Vo Rated + 0.05 % of Vo Actual Output) mV
2. Remote Current Programming (16 bit)
Resolution (0.012 % of Io Rated)
Accuracy (0.1 % of Io Rated + 0.1 % of Io Actual Output)
Resolution (0.012 % of Io Rated)
Accuracy (0.1 % of Io Rated + 0.1 % of Io Actual Output)
3. Readback Voltage
Resolution (0.012 % of Vo Rated)
Accuracy (0.1 % Vo Rated + 0.1 % of Vo Actual Output)
0~100 %, 0~5 V or 0~10 V, user-selectable. Accuracy and linearity:
±0.5 % of rated Vout.
0~100 %, 0~5 V or 0~10 V, user-selectable. Accuracy and linearity:
±1 % of rated Iout.
0~100 %, 0~5/10 kΩ full scale, user-selectable. Accuracy and linearity:
±1 % of rated Vout.
0~100 %, 0~5/10 kΩ full scale, user-selectable. Accuracy and linearity:
±1.5 % of rated Iout.
By electrical. Voltage: 0~0.6 V/2~15 V, or dry contact, user-selectable logic
0~5 V or 0~10 V, accuracy: 1 %, user-selectable
0~5 V or 0~10 V, accuracy: 1 %, user-selectable
TTL high (4~5 V) -OK, 0 V-Fail 500 Ω series resistance
CV: TTL high (4~5 V) source: 10 mA, CC: TTL low (0~0.6 V), sink current: 10 mA
Dry contact. Open: off, Short: on. Max. voltage at Enable/Disable in: 6 V
By electrical signal or Open/Short: 0~0.6 V or short: Remote, 4~5 V or open: Local
Open collector, Local: Open, Remote: On. Maximum voltage: 30 V, maximum sink
current: 5 mA
Vout/Iout manual adjust by separate encoders (coarse and fine adjustment selectable)
OVP/UVL manual adjust by Volt. Adjust encoder
AC on/off, Output on/off, Re-start modes (auto, safe), Foldback control (CV to CC),
Go to local control
Address selection by Voltage (or current) adjust encoder. Number of addresses: 31
RS232/485 and IEEE488.2 selection by IEEE enable switch and DIP switch
Baud rate selection: 1200, 2400, 4800, 9600 and 19200
Voltage 4 digits, accuracy: 0.5 % ±1 count
Current 4 digits, accuracy: 0.5 % ±1 count
Voltage, Current, Alarm, Fine, Preview, Foldback, Local, Output On, Front Panel Lock
V
mV
mA
mA
mA
mA
mV
mV
6
0.72
6.0
12
200
24
400
0.72
12
8
0.96
8.0
10.8
180
21.6
360
0.96
16
12.5
1.50
12.5
7.2
120
14.4
240
1.50
25
20
2.40
20
4.56
76
9.12
152
2.40
40
30
3.0
3.60
3.60
30
50
6.0
100
60

Related parts for GP485A