GP485A TDK Corporation, GP485A Datasheet - Page 24

no-image

GP485A

Manufacturer Part Number
GP485A
Description
GPIB CONTROLLER
Manufacturer
TDK Corporation
Series
ZUPr
Datasheets

Specifications of GP485A

Accessory Type
Controller
For Use With/related Products
ZUP Series
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q4846340
Specifications Genesys™ 2400 W
*12: For cases where conformance to various safety standards
24
1.6 Interface RS-232 & RS-485 or Optional GPIB / LAN Interface
Model
4. Readback Current
Resolution (0.012 % of Io Rated)
Accuracy (0.3 % of Io Rated + 0.1 % of Io Actual Output) mA
(*11)
5. OVP/UVL Programming
Resolution (0.1 % of Vo Rated)
Accuracy (1 % of Vo Rated)
2.1. Input Characteristics
1. Input voltage/freq. (*12)
2. Maximum Input current at 100 % load
3. Power Factor (Typ)
4. Efficiency (*13)
5. Inrush Current (*14)
6. Hold-up time (Typ)
2.2 Auxiliary Output
1. 15 V output
2. 5 V output
2.3 Power Supply Configuration
1. Parallel operation
2. Series operation
2.4 Environmental Conditions
1. Operating temperature
2. Storage temperature
3. Operating humidity
4. Storage humidity
5. Vibration
6. Shock
7. Altitude
8. RoHS Compliance
2.5 EMC
1. Applicable Standards:
2. ESD
3. Fast transients
4. Surge immunity
5. Conducted immunity
6. Radiated immunity
7. Magnetic field immunity
8. Voltage dips
9. Conducted emission
10. Radiated emission
Single Phase, 230 V models
3-Phase, 208 V models
(UL, IEC, etc.) is required, to be described as 190 – 240 V AC
(50/60 Hz) for 3-phase 208 V models.
V
mA
mV
mV
GEN
V AC
A
A
%
A
ms
15 V ±5 %, 0.2 A Max. load, Ripple & Noise 50 mV p-p.
Referenced internally to the negative output potential.
5 V ±5 %, 0.2 A Max. load, Ripple & Noise 50 mV p-p.
Referenced internally to IF_com potential.
Up to 4 identical units in master/slave mode
Up to 2 identical units with external diodes. 600 V max. to chassis ground
0~50 °C, 100 % load
–20~85 °C
20~90 % RH (non-condensing)
10~95 % RH (non-condensing)
MIL-810F, method 514.4, The EUT is fixed to the vibrating surface
Less than 20 g, half sine, 11 ms, unit is unpacked
Operating: 10,000 ft (3,000 m), Derate output current by 2 % / 100 m
above 2,000 m. Alternatively, derate maximum ambient temperature by
1 °C / 100 m above 2,000 m. Non-operating: 40,000 ft (12,000 m)
Complies with the requirements of RoHS directive.
IEC1000-4-2. Air-disch. –8 kV, contact disch. –4 kV
IEC1000-4-4. 2 kV
IEC1000-4-5. 1 kV line to line, 2 kV line to ground
IEC1000-4-6, 3 V
IEC1000-4-3, 3 V/m
EN61000-4-8, 1 A/m
EN61000-4-11
EN55022A, FCC part 15-A, VCCI-A
EN55022A, FCC part 15-A, VCCI-A
*13: For cases where conformance to various safety standards
(UL, IEC, etc) is required, to be described as 190–240 V AC
(50/60 Hz) for single phase and 3-Phase 208 V models, and
380~415 V AC (50/60 Hz) for 3-Phase 400 V models.
8
36
1200
8
80
8-300
Single Phase, 230 V models: 170~265 V AC, 47~63 Hz
3-Phase, 208 V models: 170~265 V AC, 47~63 Hz
17
10.5
Single Phase models: 0.99@230 V AC, rated output power.
3-Phase models: 0.94@208 V AC, rated output power
84
Single Phase and 3-Pase 208 V models: Less than 50 A
10 ms for Single Phase and 3-Phase 208 V models. Rated output power.
10
28.8
960
10
100
10-240
17
10.5
84
16
18
600
16
160
16-150
17
10.5
84
20-120
16.3
9.8
86
20
14.4
480
20
200

Related parts for GP485A