GP485A TDK Corporation, GP485A Datasheet - Page 18

no-image

GP485A

Manufacturer Part Number
GP485A
Description
GPIB CONTROLLER
Manufacturer
TDK Corporation
Series
ZUPr
Datasheets

Specifications of GP485A

Accessory Type
Controller
For Use With/related Products
ZUP Series
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q4846340
Specifications Genesys™ GEN/GENH 750 W / 1500 W
*1: For cases where conformance to various safety standards
18
1.6 Interface RS232 & RS485 or Optional GPIB / LAN Interface
Model
4. Readback Current
Resolution (0.012 % of Io Rated)
Accuracy (0.1 % of Io Rated + 0.3 % of Io Actual Output)
Resolution (0.012 % of Io Rated )
Accuracy (0.1 % of Io Rated + 0.3 % of Io Actual Output)
5. OVP/UVL Programming
Resolution (0.1 % of Vo Rated)
Accuracy (1 % of Vo Rated)
2.1 Input Characteristics
1. Input voltage/freq. (*1)
2. Power Factor
3. EN61000-3-2,3 compliance
4. Input current 100/200 V AC
5. Inrush current 100/200 V AC
6. Hold-up time
2.2 Power Supply Configuration
1. Parallel operation
2. Series operation
2.3 Environmental Conditions
1. Operating temperature
2. Storage temperature
3. Operating humidity
4. Storage humidity
5. Vibration
6. Shock
7. Altitude
2.4 EMC
1. Applicable Standards:
2. ESD
3. Fast transients
4. Surge immunity
5. Conducted immunity
6. Radiated immunity
7. Conducted emission
8. Radiated emission
9. Voltage dips
10. Conducted emission
11. Radiated emission
(UL, IEC etc.) is required, to be described as 100-240 V AC (50/60 Hz).
V
mA
mA
mA
mA
mV
mV
85~265 V AC continuous, 47~63 Hz, single phase
0.99 @100/200 V AC, rated output power
Complies with EN61000-3-2 class A and EN61000-3-3 at 20~100 %
output power
10.5 A / 5 A (750 W), 21 A / 11 A (1500 W)
Less than 25 A (750 W), Less than 50 A (1500 W)
More than 20 ms, 100 V AC, at 100 % load
Up to 4 units in master/slave mode with single wire current balance
connection
Up to 2 units with external diodes. 600 V max. to chassis ground
0~50 °C, 100 % load
–20~70 °C
30~90 % RH (non-condensing)
10~95 % RH (non-condensing)
MIL-810E, method 514.4, test cond. I-3.3.1
The EUT is fixed to the vibrating surface
Less than 20 g, half sine, 11 ms unit is unpacked
Operating: 10,000 ft (3,000 m), Derat output current by 2 %/100 m
above 2,000 m, Non-operating: 40,000 ft (12,000 m)
IEC1000-4-2. Air-disch. –8 kV, contact disch. –4 kV
IEC1000-4-4. 2 kV
IEC1000-4-5. 1 kV line to line, 2 kV line to ground
IEC1000-4-6, 3 V
IEC1000-4-3, 3 V/m
EN55022B, FCC part 15J-B,VCCI-B
EN55022A, FCC part 15-A,VCCI-A
EN61000-4-11
EN55022B, FCC part 15-B, VCCI-B
EN55022A, FCC part 15-A, VCCI-A
All specifications subject to change without notice.
6
12
400
24
800
6
60
8
10.8
360
21.6
720
8
80
12.5
7.2
240
14.4
480
12
125
20
4.56
152
9.12
304
20
200
30
30
3.0
100
6
200
300