General Specifications Genesys™ 10 kW / 15 kW
38
2.1 Input Characteristics
1. Input voltage / freq. (range)
2. No. of phases
3. Dropout voltage
4. Input current 180 / 360 / 432 V AC
5. Inrush current
6. Power Factor
7. Leakage current
8. Input Protection
9. Input Overvoltage Protection
10. Phase Imbalance
2.2 Power Supply Configuration
1. Parallel Operation
2. Series Operation
2.3 Environmental Conditions
1. Operating temperature
2. Storage temperature
3. Operating humidity
4. Storage humidity
5. Vibration & Shock (208 / 400 V AC)
6. Altitude
7. Audible Noise
208 V AC (180~253); 400 V AC (360/440); 480 V AC (432~528), all 47 – 63 Hz
3 Phases (Wye or Delta) 4 wire total (3 Phase and 1 protective earth ground)
180 / 360 / 432 V
10 kW – 45 / 23 / 20 A; 15 kW – 64 /32 / 27 A. All at full rated output power.
Not to exceeed full rated Input current. See Para 2.4
0.88 Passive
3.5 mA (EN60950) max.
208 V AC Circuit Breaker; 400 V AC, 480 V AC – Line Fuse
Unit shall not be damaged by line overvoltage with max. duration of 100 µs.
Up to 120 % of nominal AC input voltage.
≤ 5 % on Three Phase Input
Up to four (4) identical units may be connected in Master/Slave Mode with
‘Single’ wire connection. In advanced parallel feature, the current of Master unit,
multiplied by number of units connected in parallel, is made available on digital
interface and displayed on front panel of Master unit. Remote analog current
monitor of the Master is scaled to output current of the Master unit (only).
Possible (with external diodes), up to 2 identical units with total output
not to exceed ±600 V from chassis ground.
0~50 °C, 100 % load
–20~70 °C
20~80 % RH (non-condensing)
10~90 % RH (non-condensing)
ASTM D4169, Standard practice for performance testing of shipping containers
and systems. Shipping unit: single package. Assurance level: Level II. Acceptance
criteria: Criterion 1 – No product damage. Criterion 2 – Packaging is intact.
Distribution cycle: 12 – Air (intercity) and motor freight (local), unitized is used
Operating: 50 °C up to 7,500 ft (2,500 m),
45 °C from 7,501 to 10,000 ft (2,501 – 3,000 m)
Non operating 40,000 ft (12,000 m)
65 dBA at full load, measured 1 m from front panel