GP485A TDK Corporation, GP485A Datasheet - Page 26

no-image

GP485A

Manufacturer Part Number
GP485A
Description
GPIB CONTROLLER
Manufacturer
TDK Corporation
Series
ZUPr
Datasheets

Specifications of GP485A

Accessory Type
Controller
For Use With/related Products
ZUP Series
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q4846340
Specifications Genesys™ 3.3 kW /
*1: Minimum voltage is guaranteed to maximum 0.2 % of rated output
*2: Minimum current is guaranteed to maximum 0.4 % of rated output
*3: Single-Phase and 3-Phase 208 V models: 170~265 V AC, constant
26
1.0 Model
1. Rated output voltage (*1)
2. Rated output current (*2)
3. Rated output power
1.1 Constant Voltage Mode
1. Max. line regulation
2. Max. load regulation
3. Ripple and noise p-p 20 MHz (*5)
4. Ripple RMS 5 Hz ~ 1 MHz
5. Remote sense compensation/wire
6. Temperature coefficient
7. Temperature stability
8. Warm-up drift
9. Up-prog. response time, 0~Vo Rated (*6)
10. Down-prog. response time
11. Transient response time
1.2 Constant Current Mode
1. Max. line regulation (0.01 % of rated Io + 2 mA) (*3) mA
2. Max. load regulation
3. Ripple RMS 5 Hz~1 MHz (*9)
4. Load regulation thermal drift
5. Temperature coefficient
6. Temperature stability
7. Warm-up drift
voltage.
current.
load. 3-Phase 400 V models: 342~460 V AC, constant load.
(0.01 % of rated Vo + 2 mV ) (*3)
(0.015 % of rated Vo + 5 mV ) (*4)
(0.02 % of rated Io + 5 mA) (*8)
Full-load (*6)
No-load (*7)
Genesys™ 5 kW
GEN
V
A
W
mV
mV
mV
mV
V
ppm/°C
ms
ms
ms
ms
mA
mA
ppm/°C
*4: From No-Load to Full-Load, constant input voltage. Maximum drop
*5: For 8 V~300 V models: Measured with JEITA RC-9131A (1:1) probe.
*6: From 10 % to 90 % or 90 % to 10 % of Rated Output Voltage, with rated,
in Remote Sense.
For 600 V model: Measured with 10:1 probe.
resistive load.
Time for output voltage to recover within 0.5 % of its rated output
for a load change 10 – 90 % of rated output current. Output set-point:
10 – 100 %, local sense. Less than 1 ms for models up to and
including 100 V. 2 ms for models above 100 V.
85
1300
Less than 0.1 % of rated output current over 30 minutes following
load change.
200 ppm/°C /
following 30 minutes warm-up.
0.05 % of rated Iout over 8 hrs interval following 30 minutes warm-up.
Constant line, load & temperature.
8~40 V model: Less than ±0.5 % rated output current
over 30 minutes following power On.
60~600 V model: Less than ±0.25 % of rated output current
over 30 minutes following power On.
8-400
8
400
3200
2.8
6.2
60
8
2
100 ppm/°C of rated output voltage, following 30 minutes warm-up.
0.05 % of rated Vout over 8 hrs interval following 30 minutes warm-up.
Constant line, load & temperature.
Less than 0.05 % of rated output voltage + 2 mV over 30 minutes
following power On.
20
500
42
8-600
8
600
4800
0.8
6.2
75
10
2
15
400
300
600
1950
100 ppm/°C
10-330
10
330
3300
3
6.5
60
8
2
600
35
71
1200
from rated output current,
10-500
10
500
5000
1.0
6.5
75
10
2
500
250
500
1800
80 /
(8 ~16 V model)
(20 ~600 V model)
15-220
15
220
3300
3.5
7.25
60
8
2
700
24
49
880
30
100 /
800
155
310
1400
16-310
16
310
4960
1.6
7.4
75
10
2
50
3300
4
8
60
8
2
800
18.5
38
6
20-165
20
165
250
1000
20-250
20
250
5000
2
8
75
10
2
700
125

Related parts for GP485A