Specifications Genesys™ 2400 W
20
*1: Minimum voltage is guaranteed to maximum 0.2 %
*2: Minimum current is guaranteed to maximum 0.4 %
*3: 3-Phase 208 V models: At 208 V AC input voltage.
1.0 Model
1. Rated output voltage (*1)
2. Rated output current (*2)
3. Rated output power
4. Efficiency (*3)
1.1 Constant Voltage Mode
1. Max. line regulation (0.01 % of Vo + 2 mV) (*4)
2. Max. load regulation (0.015 % of Vo + 5 mV) (*5)
3. Ripple and noise p-p 20 MHz (*9)
4. Ripple RMS 5 Hz~1 MHz (*10) mV
5. Remote sense compensation/line
6. Temperature coefficient
7. Up-prog. response time, 0~Vo Rated (*7)
8. Down-prog. response time full-load (*7)
9. Down-prog. response time no-load (*8)
10. Transient response time
1.2 Constant Current Mode
1. Max. line regulation (0.01 % of Io + 2 mA) (*4)
2. Max. load regulation (0.02 % of Io + 5 mA) (*6)
3. Ripple RMS 5 Hz~1 MHz (*7)
4. Temperature coefficient
1.3 Protective Functions
1. OCP
2. OCP Foldback
3. OVP type
4. OVP trip point
5. Over Temperature Protection
of rated output voltage.
of rated output current.
With rated output power.
GEN
V
A
W
%
mV
mV
mV
8
V
ppm/°C
ms
ms
ms
mA
mA
mA
ppm/°C
V
*4: 3-Phase 208 V models: 170~265 V AC, constant load.
*5: From No-load to Full-load, constant input voltage.
*6: For load voltage change, equal to the unit voltage rating,
Maximum drop in Remote Sense.
constant input voltage.
User-selectable.
Inverter shut-down, manual reset by AC input recycle or by OUT button
or by communication port.
0.5 ~10
User-selectable, latched or non-latched
8-300
8
300
2400
84
2.8
6.2
60
8
2
100 ppm/°C of rated output voltage, following 30 minutes warm up
15 ms, N.L / F.L,
resistive load
10
500
Time for output voltage to recover within 0.5 % of its rated output
for a load change 10 – 90 % of rated output curent. Output set-point:
10 – 100 %, local sense. Less than 1 ms for models up to and
including 100 V. 2 ms for models above 100 V
32
65
1200
100 ppm/°C from rated output voltage, following 30 minutes warm up
0~105 % Constant Current
Output shut-down when power supply change from CV to CC.
10-240
10
240
2400
84
3
6.5
60
8
2
600
26
53
960
0.5~12
16-150
16
150
2400
84
3.6
7.4
60
8
2
30
700
17
35
600
1~19
1~24
20-120
20
120
2400
86
4
8
60
8
2
800
14
29
480