GP485A TDK Corporation, GP485A Datasheet - Page 14

no-image

GP485A

Manufacturer Part Number
GP485A
Description
GPIB CONTROLLER
Manufacturer
TDK Corporation
Series
ZUPr
Datasheets

Specifications of GP485A

Accessory Type
Controller
For Use With/related Products
ZUP Series
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q4846340
Specifications Genesys™ GEN/GENH 750 W / 1500 W
*1: Minimum voltage is guaranteed to maximum 0.2 % of Vo Rated.
*2: Minimum current is guaranteed to maximum 0.4 % of Io Rated.
*3: At maximum output power.
14
1.0 Model
1. Rated output voltage (*1)
2. Rated output current (*2)
3. Rated output power
4. Efficiency at 100/200 V AC (*3)
1.0 Model
1. Rated output voltage (*1)
2. Rated output current (*2)
3. Rated output power
1.0 Model
1. Rated output voltage (*1)
2. Rated output current (*2)
3. Rated output power
4. Efficiency at 100/200 V AC (*3)
1.1 Constant Voltage Mode
1. Max. line regulation (0.01 % of Vo + 2 mV) (*4)
2. Max. load regulation (0.01 % of Vo + 2 mV) (*5)
3. Ripple and noise p-p 20 MHz (*9)
4. Ripple RMS 5 Hz~1 MHz (*9)
5. Remote sense compensation/line
6. Temperature coefficient
7. Up-prog. response time, 0~Vo Rated
8. Down-prog. response time full-load
9. Down-prog. response time no-load
10. Transient response time (*8)
1.2 Constant Current Mode
1. Max. line regulation (0.01 % of Io + 2 mA) (*4)
2. Max. load regulation (0.02 % of Io + 5 mA) (*6)
3. Ripple RMS 5 Hz~1 MHz (*7)
4. Max. line regulation (0.01 % of Io + 2 mA) (*4)
5. Max. load regulation (0.02 % of Io + 5 mA) (*6)
6. Ripple RMS 5 Hz~1 MHz (*7)
7. Temperature coefficient
1.3 Protective Functions
1. OCP
2. OCP Foldback
3. OVP type
4. OVP trip point
5. Over Temperature Protection
GEN
V
A
W
%
GEN
V
A
W
GENH
V
A
W
%
mV
mV
mV
mV
V
ppm/°C
ms
ms
ms
mA
mA
mA
mA
mA
mA
ppm/°C
V
*4: 85~132 V AC or 170~265 V AC, constant load.
*5: From No-load to Full-load, constant input voltage.
*6: For load voltage change, equal to the unit voltage rating,
constant input voltage.
6-200
6
200
1200
77/79
6-100
6
100
600
6-100
6
100
600
76/78
2.6
2.6
60
8
1
100 ppm/°C of rated output voltage, following 30 minutes
warm up
80 ms, N.L / F.L, resistive load
10
500
Less than 1 ms for models up to and including 100 V. 2 ms
for models above 100 V
12
25
200
22
45
400
100 ppm/°C from rated output voltage, following 30 minutes warm up
0~105 % Constant Current
Output shut-down when power supply change from CV to CC.
User-selectable.
Inverter shut-down, manual reset by AC input recycle or by OUT button
or by communication port.
0.5 ~7.5
User-selectable, latched or non-latched
8-180
8
180
1440
78/81
8-90
8
90
720
8-90
8
90
720
77/80
2.8
2.8
60
8
1
50
600
11
23
180
20
41
360
0.5 ~10
12.5-120
12.5
120
1500
81/84
12.5-60
12.5
60
750
12.5-60
12.5
60
750
81/84
3.3
3.3
60
8
1
50
700
8.0
17
120
14
29
240
1~15
20-76
20
76
1520
83/86
20-38
20
38
760
20-38
20
38
760
82/85
4
4
60
8
1
50
800
5.8
12.6
76
9.6
20.2
152
1~24
30-50
30
50
1500
83/86
30-25
30
25
750
30-25
30
25
750
83/87
5
5
60
8
1.5
80
900
4.5
10
63
7.0
15
125
2~36

Related parts for GP485A