ADM1034ARQZ-R7 ON Semiconductor, ADM1034ARQZ-R7 Datasheet - Page 4

no-image

ADM1034ARQZ-R7

Manufacturer Part Number
ADM1034ARQZ-R7
Description
IC THERM/FAN SPEED CTLR 16-QSOP
Manufacturer
ON Semiconductor
Datasheet

Specifications of ADM1034ARQZ-R7

Function
Fan Control, Temp Monitor
Topology
ADC, Comparator, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-QSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
ELECTRICAL CHARACTERISTICS
Power Supply
Temperature−to−Digital Converter
Open−Drain Digital Outputs (ALERT, THERM, FAN_FAULT, DRIVE1, DRIVE2) (Note 3)
Digital Input Leakage Current (TACH1, TACH2)
Digital Input Logic Levels (TACH1, TACH2)
Open−Drain Serial Data Bus Output (SDA)
Serial Data Bus Inputs (SCL, SDA)
Analog Inputs (Location, REF)
1. Typicals are at T
2. Operation at 5.5 V is guaranteed by design, not production tested.
3. Recommend use of 100 kW pullup resistors for all open−drain outputs from the ADM1034.
4. Guaranteed by design, not production tested.
5. SMBus timeout disabled by default. See the SMBus section for more information.
Supply Voltage, V
Supply Current, I
Undervoltage Lockout Threshold
Power−On Reset Threshold
Internal Sensor Accuracy
Resolution
External Diode Sensor Accuracy
Resolution
Remote Sensor Source Current
Series Resistance Cancellation
Power Supply Sensitivity
Conversion Time (Local Temperature)
Conversion Time (Remote Temperature)
Total Conversion Time
Output Low Voltage, V
High Level Output Leakage Current, I
Input High Current, I
Input Low Current, I
Input Capacitance, C
Input High Voltage, V
Input Low Voltage, V
Hysteresis
Output Low Voltage, V
High Level Output Leakage Current, I
Input High Voltage, V
Input Low Voltage, V
Hysteresis
Input Resistance
specifications are tested at logic levels of V
Parameter
CC
CC
IL
A
IH
IL
IL
(Note 2)
IN
IH
IH
= 25°C and represent most likely parametric norm. Standby current typ. is measured with V
OL
OL
OH
OH
(T
A
Interface inactive, ADC active
Standby mode
+20°C ≤ T
−40°C ≤ T
−40°C ≤ T
−40°C ≤ T
−40°C ≤ T
High level
Mid level
Low level
Averaging enabled
Averaging enabled
Averaging enabled
I
V
−V
V
I
V
OUT
OUT
= T
OUT
IN
OUT
IL
IN
= 0
MIN
= 0.8 V for a falling edge and V
= −6.0 mA; V
= V
= −6.0 mA; V
= V
= V
Test Conditions / Comments
to T
CC
CC
CC
D
A
A
D
D
≤ +60°C
≤ +100°C
≤ +100°C; −40°C ≤ T
≤ +100°C; T
≤ +100°C; +20°C ≤ T
; V
MAX
http://onsemi.com
CC
, V
= 3 V
CC
CC
CC
= +3 V
= V
4
A
MIN
= +40°C
to V
A
A
MAX
≤ +100°C
≤ +60°C
IH
, unless otherwise noted. (Note 1)
= 2.1 V for a rising edge.
−1.0
−0.3
Min
3.0
1.0
2.0
2.1
80
0.03125
0.03125
3.30
±1.0
±0.5
±1.0
±1.0
Typ
500
500
125
2.5
5.5
0.1
7.0
0.1
87
33
11
32
75
±1.25
1000
CC
Max
±2.0
±2.5
±1.0
±2.5
+0.8
900
160
3.6
3.0
2.4
0.4
1.0
1.0
5.5
0.4
1.0
0.8
= 3.3 V. Timing
mV p−p
Unit
%/V
mA
mV
ms
ms
ms
kW
mA
mA
mA
mA
mA
pF
mA
°C
°C
°C
°C
W
V
V
V
V
V
V
V
V
V