ADM1034ARQZ-R7 ON Semiconductor, ADM1034ARQZ-R7 Datasheet - Page 37

no-image

ADM1034ARQZ-R7

Manufacturer Part Number
ADM1034ARQZ-R7
Description
IC THERM/FAN SPEED CTLR 16-QSOP
Manufacturer
ON Semiconductor
Datasheet

Specifications of ADM1034ARQZ-R7

Function
Fan Control, Temp Monitor
Topology
ADC, Comparator, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-QSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 64. Register 0x42/43, Remote 1 Temp Registers, Power−On Default 0x00, Lock = N, S/W Reset = Y
Table 65. Register 0x44/45, Remote 2 Temp Registers, Power−On Default 0x00, Lock = N, S/W Reset = Y
Table 66. Register 0x4A/4B, TACH1 Period, Power−On Default 0xFF, Lock = N, S/W Reset = Y
Table 67. Register 0x4C/4D, TACH2 Period, Power−On Default 0xFF, Lock = N, S/W Reset = Y
Table 68. Register 0x4E, THERM % On−Time, Power−On Default 0x00, Lock = N, S/W Reset = Y
Table 69. Register 0x4F, Status 1, Power−On Default 0x00, Lock = N, S/W Reset = Y
<12:5>
<12:5>
<15:8>
<15:8>
<7:0>
<4:0>
<4:0>
<7:0>
<7:0>
Bit
Bit
Bit
Bit
Bit
Bit
7
6
5
4
3
2
1
0
THERM % On−Time
Local Temp High
Local Temp Low
Remote 1 Temp High
Remote 1 Temp Low
Remote 1 Diode Error
Remote 2 Temp High
Remote 2 Temp Low
Remote 2 Diode Error
Remote 1 Temperature LSB
Remote 1 Temperature MSB
Remote 2 Temperature LSB
Remote 2 Temperature MSB
Fan 1 Period Count, LSB
Fan 1 Period Count, MSB
Fan 2 Period Count, LSB
Fan 2 Period Count, MSB
Name
Name
Name
Name
Name
Name
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Represents the % time of THERM activity within the time window set by the
configuration bits.
A 1 indicates that the local high limit has been tripped.
A 1 indicates that the local low limit has been tripped.
A 1 indicates that the Remote 1 high limit has been tripped.
A 1 indicates that the Remote 1 low limit has been tripped.
A 1 indicates that a short or an open has been detected on the Remote 1
temperature channel. This test is completed once on each conversion.
A 1 indicates that the Remote 2 high limit has been tripped.
A 1 indicates that the Remote 2 low limit has been tripped.
A 1 indicates that a short or an open has been detected on the Remote 2
temperature channel. This test is completed once on each conversion.
This register contains the LSBs of the last measured Remote 1 temperature
value. Resolution = 0.03125°C.
This register contains the LSBs of the last measured Remote 1 temperature
value. Resolution = 1°C.
This register contains the LSBs of the last measured Remote 2 temperature
value. Resolution = 0.03125°C.
This register contains the MSBs of the last measured Remote 2 temperature
value. Resolution = 1°C.
This register contains the LSBs of the last measured Fan 1 revolution count.
This register contains the MSBs of the last measured Fan 1 revolution count.
This register contains the LSBs of the last measured Fan 2 revolution count.
This register contains the MSBs of the last measured Fan 2 revolution count.
http://onsemi.com
37
Description
Description
Description
Description
Description
Description