ADM1034ARQZ-R7 ON Semiconductor, ADM1034ARQZ-R7 Datasheet - Page 33

no-image

ADM1034ARQZ-R7

Manufacturer Part Number
ADM1034ARQZ-R7
Description
IC THERM/FAN SPEED CTLR 16-QSOP
Manufacturer
ON Semiconductor
Datasheet

Specifications of ADM1034ARQZ-R7

Function
Fan Control, Temp Monitor
Topology
ADC, Comparator, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-QSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 42. Register 0x0A, Mask Register 3, Power−On Default 0x00, Lock = N, S/W Reset = Y
Table 43. Register 0x0B, Local High Limit, Power−On Default 0x8B, Lock = N, S/W Reset = N
Table 44. Register 0x0C, Local Low Limit, Power−On Default 0x54, Lock = N, S/W Reset = N
Table 45. Register 0x0D, Local THERM Limit, Power−On Default 0x95, Lock = Y, S/W Reset = Y
Table 46. Register 0x0E, Remote 1 High Limit, Power−On Default 0x8B, Lock = N, S/W Reset = N
Table 47. Register 0x0F, Remote 1 Low Limit, Power−On Default 0x54, Lock = N, S/W Reset = N
Table 48. Register 0x10, Remote 1 THERM Limit, Power−On Default 0x95, Lock = Y, S/W Reset = N
Table 49. Register 0x11, Remote 2 High Limit, Power−On Default 0x8B, Lock = N, S/W Reset = N
<7:0>
<7:0>
<7:0>
<7:0>
<7:0>
<7:0>
<7:0>
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
7
6
5
4
3
2
1
0
Fan 1 Stalled
Fan Alarm Speed
Fan 2 Stalled
Reserved
Reserved
Reserved
Reserved
Reserved
Local High Limit
Local Low Limit
Local THERM Limit
Remote 1 High Limit
Remote 1 Low Limit
Remote 1 THERM
Limit
Remote 2 High Limit
Name
Name
Name
Name
Name
Name
Name
Name
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R
A 1 disables the corresponding interrupt status bit, preventing it from causing the
interrupt output. The status bit is not affected. Default = 0.
A 1 disables the corresponding interrupt status bit, preventing it from causing the
interrupt output. The status bit is not affected. Default = 0.
A 1 disables the corresponding interrupt status bit, preventing it from causing the
interrupt output. The status bit is not affected. Default = 0.
Reserved. Default = 0.
Reserved. Default = 0.
Reserved. Default = 0.
Reserved. Default = 0.
Reserved. Default = 0.
When the local temperature exceeds this temperature, the corresponding interrupt
status bit is set.
When the local temperature falls below this temperature, the corresponding interrupt
status bit is set.
When the local temperature exceeds this temperature, the corresponding status bit is
set and the THERM output is activated.
When the Remote 1 temperature exceeds this temperature, the corresponding interrupt
status bit is set.
When the Remote 1 temperature falls below this temperature, the corresponding
interrupt status bit is set.
When the Remote 1 temperature exceeds this temperature, the corresponding status bit
is set and the THERM output is activated.
When the Remote 2 temperature exceeds this temperature, the corresponding interrupt
status bit is set.
http://onsemi.com
33